Manual

FILTER
THE FILTER MENU
The parameters on the Filter Menu are all used to tune
the Ego9’s software filters which prevent the Ego9 from
firing unless all of the necessary conditions are met. The
factory default settings will be suitable for most set-ups,
however certain loader and trigger set-ups may require
modification of one or more of these parameters:
DBOUNCE
THE DEBOUNCE PARAMETER
The DBOUNCE parameter is used to combat any trigger
bounce that might occur in the Ego9 and can be set
between level 1 and level 9 in one level increments.
> LEVEL 9:
Level 9 providing the most filtering.
> LEVEL1:
Level 1 providing the least filtering.
> CANCEL:
Cancel editing and leave the parameter
unchanged.
EMPTY
THE BREECH EMPTY TIME PARAMETER
In order for the BBSS to function correctly it must first
detect that the bolt is fully retracted and the breech is
empty, and then detect that a paintball is loaded into
the breech before the Ego9 is allowed to fire.
Slots or holes in some third party bolts can fool
the BBSS
and so this parameter is used to specify a
minimum time that the breech must be empty. The
parameter can be set between 1.0 and 20.0ms in 0.5ms
increments.