THE TRIGGER CONT...
The Magnet Return Strength Screw is used to adjust the amount
of force with which the trigger is returned to its rest position by
the magnet. Turn the screw clockwise to increase the amount of
force. Do not turn the screw too far or it will negate the position
of the Front Stop Trigger Screw. Turn the screw counter clockwise
to reduce the amount of force. Do not turn the screw too far or
there will not be enough force to return the trigger (SEE FIGURE
7.3).
The Micro Switch Activation Screw is used to adjust the point in
the trigger pull at which the micro-switch is activated. Turn the
screw clockwise to decrease the amount of trigger travel to the
activation point. Turn the screw counter clockwise to increase
the amount of trigger travel to the activation point (SEE FIGURE
7.4).
If you have selected SWITCH from the HARDWARE Menu and are
consequently using the micro-switch as the method of trigger
detection then check that the micro-switch activates and de-
activates fully on each trigger pull and trigger release. If you have
selected OPTO from the HARDWARE Menu and are using the
OPTO sensor as the method of trigger detection, refer to setting
the BAND HI and BAND LO (SEE PAGE 45-46) as it is crucial that the
trigger pull and trigger filters are set up together for the trigger
filtering to work correctly.
FIG 7.3
FIG 7.4