HOW TO
STRIP THE EGO8...
Lift the bolt pin and slide the bolt out of the rear of the marker.
Disconnect any hosing and unscrew the inline regulator from
the front regulator mount as detailed in the “Cleaning the Inline
Regulator” section of this Maintenance guide.
Using a 5/64” hex key remove the six screws that attach the
Ego8 rubber grips to the Ego8 grip frame (SEE FIGURE 13.1).
Unplug the solenoid and unplug the break beam sensor system
from their connections on the Ego8 circuit board
(SEE FIGURE 13.2).
Using a 1/8” hex key undo the two frame retaining screws (SEE
FIGURE 13.3)
and remove the frame from the Ego8 body, taking
care not to damage any wires (SEE FIGURE 13.4). Take the Ego8
body and turn it so that the underside of the solenoid, QEV Block
and Valve plug are all be visible and accessible (SEE FIGURE 13.5).
Using a 1/8” hex key remove the screw from the front regulator
mount that holds the LPR Body into the marker body (SEE
FIGURE 13.6)
.
WARNING: DE-GAS YOUR MARKER, DISCHARGING ANY STORED GAS
IN A SAFE DIRECTION, AND REMOVE THE BARREL, LOADER AND AIR
SYSTEM TO MAKE THE MARKER EASIER TO WORK ON.
WARNING
FIG 13.3 FIG 13.4
FIG 13.2
FIG 13.5 FIG 13.6
FIG 13.1