Manual

THE BAND LOW
PARAMETER
(BAND LO)
The BAND LO parameter is only available if OPTO has been
selected in the HARDWARE menu. BAND LO defines the point
at which the trigger is considered released and is adjustable
between 1% and 49% in 1% increments.
BASIC TRIGGER
FILTER SET-UP
95% of trigger bounce problems can be eliminated by utilizing
one of the ninexed DEBOUNCE choices (LEVEL 1-9). In
attempting to eliminate trigger bounce it is advisable to try the
ninexed DEBOUNCE choices before attempting any advanced
set up of the triggerlters.
ADVANCED TRIGGER
FILTER SET-UP
In order to optimize the Trigger Filters it is necessary to have
the BAND HI parameter set as high as possible and the BAND LO
parameter set as low as possible:
1. Select the BAND HI parameter. Observe that the graphical bar
rises and falls as the trigger is pulled and released. The actual
value of the graphical bar is displayed in the top right of the
display.
2. Set the REAR STOP TRIGGER SCREW as required, ensuring that
the bar is as close to 100% as possible when the trigger is fully
depressed against the set screw. It is advisable to allow for some
extra travel in the trigger pull once the bar has reached its
maximum value.
3. Adjust the BAND HI parameter so that when the trigger is fully
depressed the bar settles above the indicator on the left hand
side of the screen (SEE PAGE 45).
4. Select the BAND LO parameter. Observe that the graphical bar
rises and falls as the trigger is pulled and released. The actual
value of the graphical bar is displayed in the top right of the
display.
5. Set the FRONT STOP TRIGGER SCREW as equired, ensuring that
the bar is as close to 0% as possible when the trigger is fully
released against the set screw. It is advisable to allow for some
extra travel in the trigger release once the bar has reached its
minimum value.
46.
ADVANCED SET-UP