User's Manual
CLEANING THE
INLINE REGULATOR
Note: The internals of your Inline Regulator may vary
according to the model of Ego 7 that you have.
Disconnect the hosing from your Inline Regulator allowing it
to be unscrewed from the Front Regulator Mount (FRM)
(SEE FIGURE 10.1).
Turn the Inline Regulator upside down and carefully unscrew
the two sections, taking care not to lose any of the washers
that form the spring pack inside the regulator (SEE FIGURE 10.2).
By rmly gripping the exposed end of the brass regulator
piston, carefully remove the piston and spring stack in its
entirety (SEE FIGURE 10.3).
The spring pack comprises of 16 sprung washers, which
must be in the correct conguration for the inline regulator to
perform at the required pressure range (SEE FIGURE 10.4).
Insert a 1/8th inch hex key into the adjuster screw in the
bottom half of the inline regulator, and wind the screw
clockwise through the bottom section of the regulator body
(SEE FIGURE 10.5) and pull free when it will no longer turn upwards
anymore.
WARNING: DE-GAS YOUR MARKER, DISCHARGING
ANY STORED GAS IN A SAFE DIRECTION, AND REMOVE
THE BARREL, LOADER AND AIR SYSTEM TO MAKE THE
MARKER EASIER TO WORK ON.
WARNING
NOTE: THE ADJUSTER SCREW CAN ONLY BE REMOVED
BY TURNING IT UPWARDS THROUGH THE BOTTOM
SECTION OF THE INLINE REGULATOR. THE REGULATOR
WILL BECOME DAMAGED IT THE ADJUSTER SCREW IS
REMOVED INCORRECTLY.