User's Manual

SETTING
THE TRIGGER
Ego7 provides the user with the option to use either the
Micro Switch or the Opto sensor as the means of detecting
trigger pulls. Before you begin to adjust and set your trigger,
you must rst select the method of trigger detection that you
wish to use by entering the Set-Up Menu and making your
selection from the Hardware Menu (SEE PAGE 45).
There are four adjustment points on the trigger the Front
Stop Trigger Screw, the Rear Stop Trigger Screw, the
Magnet Return Strength Screw and the Micro Switch
Activation Screw.
As standard each Eclipse Ego7 comes with a factory set
trigger travel of approximately 2mm in total length; one
millimeter of travel before the ring point and one millimeter
of travel after the ring point.
The Front Stop Trigger Screw is used to set the amount
of trigger travel prior to the marker ring. Turn this screw
clockwise to reduce the amount of travel. Do not turn the
screw too far or the trigger will be pushed past thering
point and the marker will not work. Turn this screw counter
clockwise to increase the amount of trigger travel
(SEE FIGURE 7.1).
The Rear Stop Trigger Screw is used to set the amount of
travel after the marker hasred. Turn this screw clockwise to
reduce the amount of travel. Do not turn the screw too far or
the trigger will be prevented from reaching its ring point and
the marker will not work. Turn this screw counter clockwise
to increase the amount of travel (SEE FIGURE 7.2).
The Magnet Return Strength Screw is used to adjust the
amount of force with which the trigger is returned to its rest
position by the magnet. Turn the screw clockwise to increase
the amount of force. Do not turn the screw too far or it will
negate the position of the Front Stop Trigger Screw.


