Manual
THE FILTER MENU USING THE BREAK-BEAM
SENSOR SYSTEM
During the ring cycle, the breech sensor looks rst for an empty breech and
then for a paintball within the breech. Only when the sensor has detected both
conditions will it allow the Eclipse Ego to be red. The sensor software lter
allows you to ne tune the operation of the Break-Beam Sensor System by
allowing you to specify how long the sensors have to see an 'empty' breech
for and how long they have to see a ball for.
SETTING THE EMPTY
BREECH DETECTION TIME
SELECT
FWD / RAISE
BACK / LOWER
The FILTER Menu provides access to parameters that are used to control the
various software lters.
Scroll through the SET-UP Menu until the FILTER is displayed and then press
Select. This will display EMPTY, the rst item on the FILTER Menu see below.
Press the button to scroll down through each of the items on the
FILTER Menu. Once the last item has been displayed, pressing the
button will cause the rst item to be displayed.
Press the button to scroll up through each of the items on the
FILTER Menu. Once the rst item has been displayed, pressing the
button will cause the last item to be displayed.
Press the button to edit the displayed parameter.
Selecting BACK will return the display to the SET-UP Menu.
Custom and third party bolts can fool the BBSS if they have slots or holes
that allow the Break-Beam to pass through. To overcome this problem the
EMPTY parameter denes how long the Break-Beam has to be in-tact before
the breech is considered to be empty.
Scroll through the FILTER Menu until the EMPTY parameter is displayed.
The current value of the EMPTY BREECH DETECTION TIME (EMPTY) is shown on the
right hand side of the display see below.
Press the button to enter the edit function and the edit indicators
will appear on the display.
Press and release the button to increase the EMPTY value in 1 millisecond
increments. Press and hold the button to increase the EMPTY value more
rapidly.
Press and release the button to decrease the EMPTY
value in 1 millisecond increments. Press and hold
the button to decrease the EMPTY value more rapidly.
Press to save the EMPTY value and the edit indicators
will disappear from the display to indicate that the value has
been accepted.
You have now returned to the FILTER Menu.
SETTING THE BALL
DETECTION TIME
The BALL parameter denes how long a paintball has to sit in the breech
before it is considered ready to re.
Scroll through the FILTER Menu until the BALL parameter is displayed.
The current value of the BALL DETECTION TIME (BALL) is shown on the right hand
side of the display see below.
Press the button to enter the edit function and the edit indicators will
appear on the display.
Press and release the button to increase the BALL
value in 1-millisecond increments. Press and hold
the button to increase the BALL value more rapidly.
Press and release the button to decrease the BALL
value in 1-millisecond increments. Press and hold
the button to decrease the BALL value more rapidly.
Press to save the BALL value and the edit indicators
will disappear from the display to indicate that the value
has been accepted.
You have now returned to the FILTER Menu.
32
ADVANCED SET-UP
33
ADVANCED SET-UP
QUICKGUIDE