Manual

RATE OF FIRE CAP MAXIMUM RATE OF FIRE
(WITH BBSS OFF)
DWELL
The ROF CAP is used to control how fast the Ego can cycle in each of the
capped rinig modes (SEMI 2, RAMP 1, RAMP 2 and RAMP 3).
Scroll through the TIMING Menu until the ROF CAP parameter is displayed.
The current value of the MAXIMUM RATE OF FIRE is shown in balls per second
on the right hand side of the display. Press the button to enter the edit
function see below:
Press and release the
RAISE
button to increase
the
ROF CAP
value in 0.1 ball per second
increments, up to a maximum of 15.4 bps.
Press and hold the button to a maximum of
15.4 bps. Press and hold the button to
increase the
ROF CAP
value more rapidly.
Press and release the button to decrease
the ROF CAP value in 0.1 ball per second
increments, down to a minimum of 10 bps. Press
and hold the button to decrease the ROF CAP
value more rapidly.
Press to save the ROF CAP value and
the edit indicators will disappear from the display
to indicate that the value has been accepted.
You have now returned to the TIMING Menu.
The Dwell parameter controls the amount of time that the solenoid is energised
and therefore the amount of gas that is released with each shot.
Scroll through the TIMING Menu until the DWELL parameter is displayed.
The current value of the DWELL is shown on the right hand side of the display
see below.
Press the button to enter the edit function and the edit indicators
will appear on the display.
Press and release the button to increase the
DWELL time in 0.1 millisecond increments. Press
and hold the button to increase the DWELL
time more rapidly.
Press and release the button to decrease
the DWELL time in 0.1 millisecond increments.
Press and hold the button to decrease the
DWELL time more rapidly.
Press to save the DWELL time and the edit
indicators will disappear from the display to indicate
that the value has been accepted.
You have now returned to the TIMING Menu.
The OFF ROF parameter is used to control how fast the Ego cycles when the
Break-Beam Sensor System is disabled. This parameter should be set to
match the slowest speed of the loading system in use.
Scroll through the TIMING Menu until the OFF ROF parameter is displayed.
The current value of the MAXIMUM RATE OF FIRE
(WITH BBSS OFF) is shown in balls per second
on the right hand side of the display. Press
the button to enter the edit function see left.
Press and release the button to increase the
OFF ROF value in 1 ball per second increments,
up to a maximum of 15 bps. Press and hold
the button to increase the OFF ROF value
more rapidly.
Press and release the button to decrease
the OFF ROF value in 1 ball per second increments,
down to a minimum of 1 bps.Press and hold
the button to decrease the OFF ROF value
more rapidly.
Press to save the OFF ROF value and
the edit indicators will disappear from the display
to indicate that the value has been accepted.
You have now returned to the TIMING Menu.
FIRST SHOT DROP OFF
First shot drop off is a reduction in velocity of the rst paintball to be red after
the Ego has been left un-red for more than 4 minutes. The FSDO parameter is
used to dene an increase in dwell time for the 'First Shot' in order to combat
this problem.
Scroll through the TIMING Menu until the FSDO parameter is displayed.
The current value of the FIRST SHOT DROP OFF is shown on the right hand side
of the display see below.
Press the button to enter the edit function and the edit indicators will
appear on the display.
Press and release the button to increase the
FSDO value in 0.1ms increments. Press and hold
the button to increase the FSDO value more
rapidly.
Press and release the button to decrease the
FSDO value in 0.1ms increments. Press and hold
the button to decrease the FSDO value more
rapidly.
Press to save the FSDO value and the edit
indicators will disappear from the display to
indicate that the value has been accepted.
You have now returned to the TIMING Menu.
30
ADVANCED SET-UP
31
ADVANCED SET-UP
QUICKGUIDE