Manual

39
ELECTRONICS
THE MENU TREE
MAIN MENU
RAMP SET-UP *
Fire mode dependant
RAMP TYPE
STEP (Default) STEP ramping
LINEAR LINEAR ramping
RATE *
0 - 100% Percentage LINEAR RAMP rate (TYPE dependant). Default 50%
SEMI SHOTS
3 - 9 Number of shots before ramping can start. Default 3
KICK IN
3.3 - 10.0 pps Rate which the trigger has to be pulled in pulls per second (pps) before ramping starts. Default 5 pps
SUSTAIN
3.3 - 10.0 pps Rate which the trigger has to be pulled in pulls per second (pps) to maintain ramping. Default 5 pps
RESTART
0.0 - 1.0 s Time in seconds (s) after last trigger pull during which ramping can be restarted. Default 0.0 s
BACK
TIMING
DWELL
15.0 - 35.0 ms Solenoid energise time in milliseconds (ms) for each shot. Default 23 ms
FSD COMP
0.0 - 5.0 ms First shot drop-off compensation time in milliseconds (ms). Default 5.0 ms
FSD DELAY
00:00 - 04:00 First shot drop-off delay. Default 00:30 seconds
BACK
FILTER
DEBOUNCE
LEVEL 9 Use trigger de-bounce LEVEL 9 (highest level of trigger bounce ltering)
LEVEL 8 - 2 Use trigger de-bounce LEVEL 8 - 2 (Default setting 5)
LEVEL 1 Use trigger de-bounce LEVEL 1 (lowest level of trigger bounce ltering)
EMPTY
1.0 - 20.0 ms Time in milliseconds (ms) that the breech must be empty before BS looks for a paintball. Default 4.0 ms
FULL
1.0 - 20.0 ms Time in milliseconds (ms) that a paintball must be in the breech before the CS2 will re. Default 4.0 ms
BACK