ELECTRONICS
USER INTERFACE PARAMETERS
FIG-1 - PULL TM PARAMETER
Sets the minimum amount of time that the trigger
must be pulled for in order to be recognised as a
valid trigger pull.
This parameter can be set between 3.0 and 20.0
milliseconds in 0.1 increments.
FIG-2 - RELEASE TM PARAMETER
Sets the minimum amount of time that the trigger
must be released for in order to be recognised as
a valid trigger release.
This parameter can be set between 3.0 and 25.0
milliseconds in 0.1 increments.