Manual
FIG-1
FIG-3
FIG-2
FIG-4
31
ELECTRONICS
USER INTERFACE PARAMETERS
FIG-1 - FILTER MENU
The FILTER menu parameters are used to tune the
CS2 software lters to prevent the CS2 from ring
unless all of the necessary conditions are met.
Factory default settings are suitable for most
set-ups however, certain loader and trigger
set-ups may require lter adjustments.
FIG-2 - DEBOUNCE PARAMETER
This sets the amount of trigger bounce that is
allowed and can be set from level 1 to level 9.
Changing this parameter directly changes the
PULL TM and RELEASE TM parameters.
> LEVEL1: Least ltering (most bounce).
> LEVEL9: Most ltering (least bounce).
FIG-3 - EMPTY PARAMETER
This sets the amount of time that the breech has to
be empty before the CS2 registers that it is actually
empty.
This can be set between 1.0 and 20.0 milliseconds
in 0.1 increments.
FIG-4 - FULL PARAMETER
This sets the amount of time that the breech has to
be full (paintball in place) before the CS2 registers
that it is actually full.
This parameter can be set between 1.0 and 20.0
milliseconds in 0.1 increments.