Manual
Table Of Contents
- Contents
- Introduction
- Unpacking and Checking Accessories
- Installing the Displays
- Operating the Display
- OSD Keypad
- Remote Control Receiver
- LED Indicators
- Using the Display in Portrait Mode
- Using the Display in Flat or Tilted Orientation
- Using the Remote Control
- IR Command Protocol
- Turning the Display On
- Turning the Display Off
- Adjusting the Volume
- Selecting Layouts and Input Sources
- Navigating Through the Menus
- Using the Touch Screen
- Touchscreen MultiTouch Driver Installation
- Touchscreen (PQLabs) MultiTouch Platform Content
- Uninstalling the MultiTouch Driver
- Planar UltraRes Remote Monitoring Software
- External Control
- Signal Compatibility
- Color Subsampling Support
- Specifications
- Dimensions
- Troubleshooting During Installation
- Accessing Planar’s Technical Support Website
- Index

Important Waste Disposal Information
Planar UltraRes Series User Manual 5
Important Waste Disposal Information
Please recycle or dispose of all electronic waste in accordance with local, state, and
federal laws. Additional resources can be found online at
http://www.planar.com/about/green/.
Normal Usage Guidelines
Normal use of the LCD is defined as operating in the open air to prevent heat
buildup, and without direct or indirect heat sources such as lighting fixtures, heating
ducts, or direct sunlight that can cause the displays to experience high operating
temperatures. For all displays, do not block fans or ventilation openings. If the LCD
display will be installed in a recessed area with an LCD surround or enclosure, ensure
adequate openings are applied for proper air flow and ventilation.
It is up to the installer to ensure that display placement is changed, thermal shielding
is provided and/or additional ventilation is provided to keep the display within its
nominal operating parameters. Maximum ambient operating temperatures for the
Planar UltraRes Series are:
• 75” Planar UltraRes models: 0-40°C at up to 1500 meters and 0-35°C at up to
3000 meters
• 86” and 98” Planar UltraRes models: 0-35°C at up to 1500 meters and 0-30°C at
up to 3000 meters
Cooling Requirements
For optimal performance, active cooling by the installer should be planned for when
the ambient temperature anywhere in the wall is predicted to be above the specified
ambient temperature for the display.