ATD 1024Epro User Manual Pknight® Artnet-dmx 1024Epro Page 1
Pknight®ATD 1024Epro Introduction Introduction: Congratulations and thank you for purchasing the Pknight ATD 1024Epro (Artnet-dmx 1024Epro).It is a solid-state 2 universe RDM compatible DMX node designed for the highest level of portability, simplicity, and practicality.It is the perfect solution for converting from a multitude of Ethernet-based artnet to physical DMX and vice versa.
Pknight®ATD 1024Epro Introduction Warranty A. 1 months upon date of purchase, if there is function problem, we should offer the same item subjuect to goods and packing maintain perfect. B. 3 Years upon date of purchase, we will guarantee to keep the goods in repair. (not including fittings) C. Guarantee service is subject to normally using. C.All of damage by man-made (tear open the housing, tear off the sticker, unnormally using), or losing this manual, we will not guarantee.
Pknight®ATD 1024Epro Introduction Basic Setup Right out of the box, the ATD 1024Epro is factory configured to be a DMX OUTPUT device, listening to the first Art-Net Universe (0-255). It is also set as a DHCP node, so you can plug it into your existing router, and it's good to go. Pknight provides a free application (available for Windows) called Artnet-Dmx Configurator, which will find the ATD 1024Epro on your network and display its IP address.
Pknight®ATD 1024Epro Indicators Front Panel 1 5 2 4 3 Rear Panel 6 dmx 1 port 7 dmx 2 port in input mode,we need 3-Pin XLR Male to Male Adapter(not included) Pknight® Artnet-dmx 1024Epro Page 5
Indicators Pknight®ATD 1024Epro 1 2 3 Ethernet Port Power In( 9VDC ) 2p dial The Code Switch There are 4 modes as follows dmx1&2:output dmx1:input 4 5 dmx2:output dmx1:output dmx2:input dmx1&2:input LED Indicators PWR:power on,turn green STA:connections and activities,blinks slowly,Signal detected,turn yellow. Link:connect to pc or router,turn red; Signal detected,blinks fast.
Pknight®ATD 1024Epro Setting Introduction: Artnet-Dmx Configurator is a free Windows application that is used to manage compatible DMX over Ethernet nodes. The application(in the USB flash disk ) will help you find your unit's IP address and then you can set it up easily. Please follow these steps: 1.Ensure that your ATD 1024Epro is hooked up physically by an Ethernet cable 2.And connected to the same physical network (or router) as the computer on which you will run Artnet-Dmx Configurator. 3.
Pknight®ATD 1024Epro Setting 4.Once found, Double click ArtNet DMX2 and A view will appear similar to the following figure. Basic Setting page 1 2 3 4 1 Device Name is used to identify the ATD 1024Epro on the network. Any meaningful name can be used. 2 Dmx Hold time is used to set the time to hold the dmx when your dmx program stop running.
Pknight®ATD 1024Epro Setting 2.x.x.x(Auto):a static IP starting with 2.Each ATD 1024Epro has the specific ip(by Factory Default) 10.x.x.x(Auto):a static IP starting with 10.Each ATD 1024Epro has the specific ip DHCP:the router on your network is expected to automatically provide the IP address to the ATD 1024Epro. Custom IP:You can manually enter the ip address which you want 4 Default: Click it,the device will restore the factory settings.
Pknight®ATD 1024Epro 1 Setting DMX 1 UNIVERSE is the dmx1 port of the corresponding controller panel,DMX 2 UNIVERSE is the dmx2 port of the corresponding controller panel 2 Output: Input: Artnet to DMX Output DMX Input to Artnet Read-only and can not be modified. We can only go by setting the dial Switch on the panel 3 dmx port 1 listening to the first Art-Net Universe 0 dmx port 2 listening to the first Art-Net Universe 1 (Factory Default Set).
Pknight®ATD 1024Epro 5 Frame Rate Setting at which ATD 1024Epro will output the Data from DMX port (35 Frames per second is default). It also can be customized from 0-40 6 Unicast is only available when port is set to Input. Any valid IP address can be used to Unicast DMX.Send DMX to a single IP address rather than broadcast. Web Configuration Using the IP address one can access the built-in webinterface inside the ATD 1024Epro via any modern web-browser.
Pknight®ATD 1024Epro Setting 2.use the IP address to access the web-interface via your web browser.The default password is empty, click submit directly 3.