Instructions

25
2. For easy access to the storage content, pull the shelves approx. 1/3 out. A notch
on both sides of the tracks protects bottles from falling down.
3. When you want to remove/insert a shelf, hold it tilted (see below).
6
TROUBLE SHOOTING
6
MALFUNCTION
POSSIBLE CAUSE
MEASURE
The appliance does not work at all.
The plug of the appliance is not
connected to the socket.
The plug has become loose.
The socket is not supplied with
energy.
The fuse is switched off.
The voltage is too low.
Check the corresponding socket by
connecting it with another appliance.
Check the fuse box.
Compare the data on the model
plate with the data of your energy
supplier.
Unsatisfactory cooling capacity.
The door was frequently opened.
The door is not properly closed.
The appliance is overfilled.
The door seals are damaged.
Close the door properly.
Do not overfill.
Replace the seal.
No LCD display.
Main control board is defective.
PCB is defective.
Plug is defective.
Contact the aftersales service.
LCD indicates
error
.
LED is defective.
Temperature cannot be determined.
Contact the aftersales service.
Unusual noise.
The appliance is not installed on a
level, dry and solid floor.
The appliance is in contact with a
wall or another item. The bottles are
incorrectly positioned.
Realign the appliance.
Readjust the appliance.
Realign the bottles