2.1.3 Recirculation mode (without exhaust opening)
The exhaust air is led back into the kitchen, when the appliance is operated in
recirculation mode.
The exhaust air escapes via the air outlet C
The use of carbon filters to eliminate cooking vapours and odours is
permissible for recirculation mode only.
1. Close the vertical exhaust opening (A) using the cover (D); s. fig. below.
A
VERTICAL EXHAUST OPENING
C
AIR OUTLET FOR RECIRCULATION MODE
D
COVER FOR THE UNUSED EXHAUST OPENING
2. Set the switch at the bottom of the appliance to recirculation mode (F); s. fig.
below.
E
EXTRACTION MODE
F
RECIRCULATION MODE