8.2 Cleaning of the spray arms
❖ Clean the spray arms regularly as chemicals and minerals may clog the nozzles
and bearings.
HOW TO REMOVE / INSTALL THE SPRAY ARMS
1. To remove the upper spray arm (B), hold the nut (C / in the middle of the
upper dish rack) and unscrew the spray arm (s. fig. below).
A
UPPER SPRAY ARM HOLDER
B
UPPER SPRY ARM
C
NUT
2. To remove the lower spray arm (D), pull it out upwards (s. fig. below, arrow).