Instructions
37
Lighting efficiency index
A
Power consumption standby (P
s
)
0.00
W
Power consumption off (P
o
)
0.00
W
A-rated noise emission at minimum speed/
standard operation
57
dB
(2)
A-rated noise emission at maximum speed/
standard operation
63
dB
(2)
A-rated noise emission during operation at intensive
or rapid operation setting
-
Explications:
(1) measurement of air flow
Range hoods with a maximum air flow, which
is more than 650 m
3
/h at an available setting,
must automatically change to an air flow,
which is max. 650 m
3
/h.
(2) Airborne acoustical noise
According to dB(A) re 1 pW.
To determine the results, and in accordance with the requirements in relation to
the labelling of energy-related products and with regard to ecodesign requirements,
the following calculation and measurement methods were applied:
➢ Directive of the European Parliament and of the Council 2010/30/EU;
REGULATION NO 65/2014.
➢ Directive of the European Parliament and of the Council 2009/125/EC;
REGULATION NO 66/2014.
➢ EN 50564 - Electrical and electronic household and office equipment.
Measurement of low power consumption
➢ EN 60704-2-13 - Household and similar electrical appliances. Test code for the
determination of airborne acoustical noise. Particular requirements for range
hoods.
➢ EN 61591 - Household range hoods and other cooking fume extractors -
Methods for measuring performance.
6.2 Relevant data for installation
Voltage/frequency
AC 220-240V/50Hz
Grease filter/material/dishwasher-proof
1
aluminium
✓
Carbon filter *
2*CF130
Exhaust hose
✓
Installation material
✓
Instruction manual
✓
Telescopic chimney extractable from-to
54.00-102.00 cm
Installation with ventilation stack or air duct
outwards
Wall penetration = 150 mm Ø
Drilling = ca. 160 mm Ø