Instructions
63
2. Turn off the water supply and disconnect the water inlet pipe from the water
valve.
3. Remove any water from the water inlet pipe and the valve.
4. Connect the water inlet pipe with the valve again.
5. Remove the filters. Remove any water from the drain.
7.6 Decommissioning
1. When you do not operate the appliance for a certain period of time, e.g. during
holidays/vacancies, let a programme run (empty appliance) before.
2. Disconnect the plug und turn off the water supply of the appliance.
3. Leave the door slightly ajar to protect the seals and to avoid the generation of
unpleasant odours.
8. Trouble shooting
WARNING! Disconnect the appliance from the mains before you clean
or maintain it.
ERROR
POSSIBLE CAUSES
MEASURES
Appliance does not work at all.
1. The fuse in the fuse box is tripped.
2. The appliance is not supplied with
energy.
3. Low water pressure.
1. Check the fuse box.
2. Check that the appliance is supplied
with energy / the door is closed
properly / the plug is in the socket.