Instruction Manual
~ 84 ~
To avoid any damage, the sandwich layer and adhesive must resist heat.
MINIMUM DISTANCES REQUIRED FOR PROPER VENTILATION
The hob must be ventilated properly. The air inlet (D) and outlet (E) must
never be blocked or covered. Always keep the appliance in proper condition.
The top closing edge of the cabinet (X) must not be flush with the installation
opening (1). Install the closing edge in offset positioning (2) or bevel the closing
edge (3). S. fig. below.
C = VENTILATION SLOT
A
B
C
D
E
WALL CUPBOARD
➢ min. 450 mm
EXTRACTOR HOOD
➢ min. 760 mm
min.
50 mm
min.
20 mm
Air inlet
Air outlet
5 mm
The hob must be ventilated properly. The air inlet and outlet must never
be blocked or covered.