Instructions

~ 55 ~
NOTICE! Depending on frequency of use, replace the carbon filter every
three to six months. Clean the grease filter regularly for proper operation
of the motor (s. chapter CLEANING AND MAINTENANCE).
3.3 Grease filter
Always ensure that the ALUMINIUM GREASE FILTER is inserted properly.
Clean the ALUMINIUM GREASE FILTER regularly (s. chapter CLEANING AND
MAINTENANCE).
WARNING! Operate the appliance with inserted aluminium grease
filter only. Otherwise, recirculating-transported fat will deposit in the
appliance and the exhaust system. RISK OF FIRE!
4. Control panel and operation
4.1 Control panel
WARNING! The illuminant must not be covered by thermal insulation
or other materials. RISK OF FIRE!
CAUTION! Do not touch the illuminant within 30 minutes after using
the appliance. RISK OF BURNS!
NOTICE! Only switch on the illuminant while the appliance is operating.
Do not switch on the illuminant to illuminate the room.
NOTICE! Never press two buttons simultaneously.
NOTICE! To change the power level (motor speed), always press the
button « 0 » first; then you can set the desired new power level (motor
speed) using the buttons « 1 », « 2 » or « 3 ».