Datasheet
CODE STRUCTURE
INTERNAL WIRING DIAGRAM
FAILURE
Housing
Material:
Protectiondegree:
Dimensions(LxHxS):
Crosssectionoftheconductors:
Terminalsdrivingtorque:
PolyamidePA6.6classV0(UL94)
IP 40 (housing), IP 20 (terminal board)
111,5x99,0x45mm
0,2...2,5mm
2
24...12AWG
0,5...0,6Nm
General data
Safetycategory:
Ambienttemperature:
Mechanicalendurance:
Electricalendurance:
Pollutiondegree:
Rated impulse withstand voltage Uimp:
RatedinsulationvoltageUi:
Over-voltagecategory:
Weight:
category4(istantaneouscontacts)
category3(delayedcontacts)
-25°C...+55°C
>10millionsofoperations
>100.000operations
outside3,inside2
2,5kV
250V
II
0,5Kg
Supply
Ratedoperatingvoltage(Un):
MaxresidualrippleinDC:
Supplyvoltagetolerance:
RatedpowerconsumptionAC:
RatedpowerconsumptionDC::
24VAC/DC;50...60Hz
120VAC;50...60Hz
230VAC;50...60Hz
10%
±15%ofUn
<10VA
<5W
Control circuit
Protectionagainstshortcircuits:
OperatingtimeofPTC:
Maxinputresistance:
Inputcurrent:
Min.periodofstartimpulset
MIN
:
Operatingtimet
A
:
Releasingtimet
R1
:
Releasingtimeonde-energisationt
R
:
Delayedcontactsreleasingtimet
R2
:
Simultaneitytimet
C
:
resistancePTC,Ih=0,5A
intervetion>100ms,reset>3s
≤50Ω
30mA
200ms
150ms
20ms
150ms
see“CODESTRUCTURE”
innite
Output circuit
Outputcontacts:
Contactstype:
Contactsmaterial:
Max.switchingvoltage:
Max.switchingcurrentpercontact:
ConventionalfreeairthermalcurrentIth:
Contactsresistance:
Protectionfuseoutside:
Max.switchingcapacity:
Utilizationcategory(EN60947-5-1):
Utilizationcategory(UL508):
see“CODESTRUCTURE”
Forcedguidedcontacts
Silveralloy,goldplated
230
/240VAC;300VDC
6A
6A
100m
6A
1380VA/W
AC15,Ue=230V,Ie=3A;
DC13,Ue=24V,Ie=6A(6operations/minute)
C300
Conforms to the standards
Conformstothestandards:
Conformstothedirectives:
Clearanceandcreepagedistancesin
accordancewith:
Approvals:
EN 60204-1, EN 954, EN 999, EN
1037,ENISO12100-1,ENISO12100-
2,EN418,EN60529,EN61000-6-2,
EN61000-6-3,EN62326-1,EN60664-
1,EN61496-1,EN60947-1,UL508,
CSAC22.2n°14-95
2006/95/EC,2006/42/EC,2004/108/EC
EN60947-1
ULlen°E131787
K3
K3
K4
K4
F
F
N /-
L /+
S33
S34 13 23
14
24
K3
K3
K4
K4
F
F
N /-
L /+
S33
S34 13 23
14
24
Ledlights Possiblefailure
PWR
Off
CH1
Off
CH3
Off
CH2
Off
CH4
Off
•Failofpowersupplytosafetymodule;
•Wrongconnection;
•Powerwirescutdown;
•Breakdownofexternalfuses;
•Shortcircuitbetweenchannels;
•Failureofsafetymodule;
PWR
On
CH1
Off
CH3
Off
On
On
Off
CH2
On
CH4
On
Off
On
Off
•Wrongconnection;
• Stick contacts of emergency stop or the device
ofthesafety gate monitoring connected to S21-
S22;
•ShortcircuitofESPEoutputOSSD2;
• Stick contacts of the start button (monitored
start);
•Failureofsafetymodule;
PWR
On
CH1
On
CH3
Off
On
On
Off
CH2
Off
CH4
On
Off
On
Off
• Stickcontacts onthe emergencystop or on the
deviceofthesafetygatemonitoring
connectedtoS11-S12;
•ShortcircuitofESPEoutputOSSD1;
•Failureofsafetymodule;
PWR
On
CH1
Off
CH3
Off
On
On
Off
CH2
Off
CH4
On
Off
On
Off
•Wrongconnection;
•Externalcontactsstickorfailureinthe
expansionmodule;
•Inputwirescutdown;
•Opencircuitofoneorbothcontactsofemergency
stopofsafetygatemonitoring;
•Missingautomaticcycleformanualormonitored
start(startimpulse)orclosureofbothchannelsfor
theautomaticstart;
•Failureofsafetymodule;
PWR
On
CH1
On
CH3
On
Off
Off
CH2
On
CH4
Off
On
Off
•Failureofsafetymodule;
INCREASE OF THE NUMBER AND THE LOADING CAPACITY OF THE CONTACTS
TECHNICAL DATA
Ifnecessaryitispossibletoincreasethenumberandtheloadingcapacityof
theoutputcontactsbyusingexternalcontactorswithforcedguidedcontacts.
Feedbackcircuitforexternal
contactorswithautomaticstartwiring
Feedbackcircuitforexternal
contactorswithmanualormonitored
startwiring
LOGIC
CIRCUIT
LOGIC
CIRCUIT
DatatypeapprovedbyULconformstothestandardUL508(leE131787)
Notes(datatypeapprovedbyUL):
-Use60°or75°Ccopper(Cu)conductorandwiresizeNo.30-12AWG.
-Theterminaltighteningtorqueof5-7Lb-In.
-Onlyfor24VAC/DCversion,supplyfromremoteclass2sourceorlimitedvoltageandlimitedenergy.
L/+
N/-
CS AT-01V024-TFx
Kindofconnection
Voltagesupply
Vscrewterminals
M
plug-inconnectorswithscrewterminals
X plug-inconnectorswithspringterminals
02424VAC/DC±15%
120120VAC±15%
230 230VAC±15%
Delayedcontactsreleasingtime(t
R2
)
0 Fixedtime(seeTFx)
1 from0,3to3s,step0,3s
2 from1to10s,step1s
3 from3to30s,step3s
4 from30to300s,step30s
Outputconguration
0
2NO+1NCinstantaneous;2NOdelayed
1 3NOinstantaneous;2NOdelayed
x=secondsofxeddelay
CS AT-0••••• CS AT-1•••••
K1
K2
K3
K4
A2
S21
S35
S22
14
24
32
58
48
57
47
31
23
13
S34
S31
S33
S12
S11
A1
14
24
34
58
48
57
47
33
23
13
LED
PWR
LED
CH1
LED
CH2