SRTG: Gas Floor Model Rethermalizer INSTALLATION
5
1.5.3. CE GAS TABLE
Refer to the following table for gas specifications for the country of use. If the country of use is
NOT listed, refer to the information stamped on the data plate.
Country
Gas
Appliance
Category
Input
Gross
(
kW
)
Input Net
(kW)
Supply
Pressure
(mbar)
Burner
Pressure
(mbar)
Burner
Orifice
Pilot
Orifice
Governor
Nom rate
(M3/HR)
G20 I2H 14.4 20 10 #42 N22 YES 1.5
AT
G31 I3P
16
14.7 50 25.4 #53 LP16 YES 0.6
G20/G25 I2E+ 14.4 20/25 10 #42/2.58 mm N22 NO 1.5
BE
G31 I3P
16
14.7 37 25.4 #53 LP16 YES 0.6
G20 I2H 14.4 20 10 #42 N22 YES 1.5
BG
G31 I3P
16
14.7 50/37 25.4 #53 LP16 YES 0.6
G20 I2H 14.4 20 10 #42 N22 YES 1.5
CH
G31 I3P
16
14.7 50/37 25.4 #53 LP16 YES 0.6
N/A N/A N/A N/A N/A N/A N/A N/A N/A
CY
G31 I3P
16
14.7 50 25.4 #53 LP16 YES 0.6
G20 I2H 14.4 20 10 #42 N22 YES 1.5
CZ
G31 I3P
16
14.7 50/37 25.4 #53 LP16 YES 0.6
G20/G25 I2ELL 14.4 20/25 10 #42/2.58 mm N22/MF28 YES 1.5/1.8
DE
G31 I3P
16
14.7 50/37 25.4 #53 LP16 YES 0.6
G20 I2H 14.4 20 10 #42 N22 YES 1.5
DK
N/A N/A
16
N/A N/A N/A N/A N/A N/A N/A
G20 I2H 14.4 20 10 #42 N22 YES 1.5
EE
N/A N/A
16
N/A N/A N/A N/A N/A N/A N/A
G20 I2H 14.4 20 10 #42 N22 YES 1.5
ES
G31 I3P
16
14.7 50/37 25.4 #53 LP16 YES 0.6
G20 I2H 14.4 20 10 #42 N22 YES 1.5
FI
N/A N/A
16
N/A N/A N/A N/A N/A N/A N/A
G20/G25 I2Esi 14.4 20/25 10 #42/2.58 mm N22/MF28 YES 1.5/1.8
FR
G31 I3P
16
14.7 50/37 25.4 #53 LP16 YES 0.6
G20 I2H 14.4 20 10 #42 N22 YES 1.5
GB
G31 I3P
16
14.7 50/37 25.4 #53 LP16 YES 0.6
G20 I2H 14.4 20 10 #42 N22 YES 1.5
GR
N/A N/A
16
N/A N/A N/A N/A N/A N/A N/A
G20 I2H 14.4 20 10 #42 N22 YES 1.5
G25.1 I2S 14.4 25 10 #36 N22/MF28 YES 1.8
HU
G31 I3P
16
14.7 50 25.4 #53 LP16 YES 0.6