IMPORTANT FOR FUTURE REFERENCE Please complete this information and retain this manual for the life of the equipment: Model #: ___________________________ Installation and Operation Manual Covering Model Series 35, 45 and 65 The Australian Gas Association L20-290 Rev 3, (5/12) AUSTRALIA Serial #: ___________________________ Date Purchased: ____________________
THIS MANUAL MUST BE RETAINED FOR FUTURE REFERENCE FOR YOUR SAFETY DO NOT store or use gasoline or other flammable vapors or liquids in the vicinity of this or any other appliance. Do not spray aerosols in the vicinity of this appliance while it is in operation. WARNING Improper installation, alteration, service or maintenance can cause property damage, injury or death. Read the installation, operating and maintenance instructions thoroughly before installing or servicing this equipment.
Table of Contents Section Page Installation Checking your new Appliance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Assembly and Leveling Leg and Caster Adjustment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Heat Deflector Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Installation Clearances . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Gas Connection . . . . . . . . . . . . . . . . . . . . . . . . . . .
INSTALLATION CHECKING YOUR NEW APPLIANCE Your new appliance has been carefully packed into one crate. Every effort has been made to ensure that you it is delivered to you in perfect condition. As you unpack your new appliance, inspect each of the pieces for damage. If something is damaged, DO NOT sign the bill of lading. Contact the shipper immediately; the shipper is only responsible for 15 days after delivery.
INSTALLATION Heat Deflector Installation If the appliance requires a heat deflector, you will find a removable label at the rear top edge of the unit. This label has instructions for positioning and installation of the heat deflector. Refer to the label and the instructions below to install the deflector. a. Remove the two self-drilling screws from the top, back area of the appliance. b. Position the heat deflector so that the angled portion of the deflector is facing toward the front of appliance.
INSTALLATION WARNING NEVER supply the appliance with a gas other than the one that is indicated on the data plate. Using the incorrect gas type will cause improper operation and could result in serious injury or death. If you need to convert the appliance to another type of fuel, contact the dealer you purchased it from. NOTICE NEVER use an adaptor to make a smaller gas supply line fit the appliance connection.
INSTALLATION INITIAL ADJUSTMENTS It is necessary to test the operation of your appliance after your appliance has been properly installed as described in the installation section of this manual. It will most likely need to be adjusted to ensure that it will perform as designed. These adjustments must be performed by a qualified person.
INSTALLATION Lighting Instructions (continued) d. If the pilot goes out, wait 5 minutes and repeat step C. If after three tries the pilot will not remain lit, refer to the operator troubleshooting section of this manual. e. Once a pilot flame has been established, turn the gas valve knob counterclockwise to the ON position. f. Set the thermostat control knob to the desired temperature setting. The main burners will ignite and be controlled by the thermostat.
INSTALLATION CAUTION Before proceeding any further, fill the tank with WATER. Water is used for the installation adjustments because the temperature will never exceed 212°F (100°C), thereby allowing plenty of adjustment time. Never let the water level go below the MIN LEVEL mark stamped on the tank. a. Ensure that the main gas valve is shut off; remove the manifold pressure tap plug and connect an accurate pressure gauge having a range from 0 to 16 “ w.c. in 0.1” increments (0 to 4 kPa in .
OPERATION WARNING Wear protective gloves and clothing when cleaning and draining the appliance and when disposing of water. The water is extremely hot and can cause severe injuries. e. When the tank has cooled, rinse thoroughly with cool water. Continue to rinse the tank until the cleaner has been completely and thoroughly rinsed from the tank. f. Using a clean dry cloth, wipe out all of the water.
OPERATION OPERATING INSTRUCTIONS To ensure the quality of the food you cook in this appliance, follow the preparation instructions from the food manufacturer. Using the best shortening/oil makes the best fried foods. The best shortening/oil will last longer than lower grade shortening/oil and save you money. When not in use, the shortening/oil should be cooled and covered to prevent contamination. WARNING This appliance has been installed using restraining devices to prevent accidental tipping or movement.
MAINTENANCE AND ADJUSTMENTS DAILY CLEANING Your appliance should be cleaned every day to maintain peak performance, proper sanitation and appearance. Perform the following procedures daily. a. Wipe up any shortening/oil that spills onto the exterior of the appliance. This should be done with a clean soft cloth while the shortening/oil is still warm. b. Use warm water with a mild detergent to clean surfaces.
MAINTENANCE AND ADJUSTMENTS c. Remove the thermostat dial by pulling the knob straight out. DO NOT rotate the dial. d. Holding the outside of the shaft so that it DOES NOT MOVE, scrape away the sealing compound in the center of the shaft with a small flat blade screwdriver. e. Turn the adjustment screw clockwise to lower the thermostat’s temperature setting or counterclockwise to raise it. NOTE One-quarter turn of the adjustment screw changes the temperature setting approximately 24°F (13 °C). f.
MAINTENANCE AND ADJUSTMENTS e. Ensure that the drain valve is closed and replace the tube screen. f. You may now refill the tank with shortening/oil per the filling instructions in this manual. Ventilation Hood Maintenance Proper ventilation hood operation is very important for the correct operation of this appliance and the safety of personnel.
TROUBLESHOOTING Refer to this section to correct common problems that may be encountered during the course of normal operation. If applicable, a schematic is provided behind the panel containing the electrical components. Appliance does not work. Will the pilot light? Is the gas supply valve open? NO NO Open the gas valve and light pilot YES YES Reset switch and light pilot.
Model Total Gas Consumption Burner Pressure Natural Gas Burner Pressure ULPG Injector Size: Main Burners Natural Gas ULPG Injector Size: Pilot Natural Gas ULPG Minimum Tank Capacity Cooking Area Length Cooking Area Width Cooking Area Depth Overall Height Overall Width Overall Depth Shipping Weight 35 45 65 95 Mj/h 129 Mj/h 145 Mj/h 1.0 kPa 0.9 kPa 1.0 kPa 2.50 kPa 2.50 kPa 2.50 kPa 3 of 4 of 5 of 2.53 mm (#39) 2.58 mm (#38) 2.38 mm (#42) 1.59 mm (1/16") 1.59 mm (1/16") 1.51 mm (#53) 1 of 1 of 1 of 0.