The Digital Control Board system is an intricate and valuable piece of technology. For protection from power surges and electrical
shorts, consult the wire diagram below to ensure your power source is sufficient for the operation of the unit.
PB – ELECTRIC REQUIREMENTS
110-120V, 2.1AMP, 60HZ, 250W, 3-PRONG GROUNDED PLUG
: Electrical components, passed by product safety testing and
certification services, comply with a testing tolerance of ± 5-10 percent.
LOCATE AND REMOVE
THE FOUR SCREWS
OF ACCESS PANEL ON
UNDERSIDE OF UNIT
FUEL INPUT
RATING:
1.12 KG/H
(2.48 LB/H)
ELECTRICAL
RATING:
250W, 2.1A, 120V
INDEX
W : WHITE
Y : YELLOW
P : PURPLE
R : RED
K : BLACK
G : GREEN
P
P
R
Y
Y
YP
K
K
W
G
W
W
W
R R
WW
W
W
YY
K
W
IGNITER ASSEMBLY /
HD CARTRIDGE HEATER
200W, 120V, 1.6 AMP
0.375” X 5.000
BURN POT
DRAFT FAN
120V, 50/60HZ,
0.46 AMP, 1 PHASE
GROUNDED
POWER CORD
VW-1, 105°C/221°F,
18-3 STANDARD CSA
AUGER MOTOR
& FEED SYSTEM
120V, 50/60HZ,
0.46 AMP, 2 RPM MOTOR
GROUND
GRILL
PROBE
TEMPERATURE PROBE
SPADE CONNECTORS
FAST-BLOW FUSE
5 AMP
CONTROL BOARD