User Manual
P
r
o
pane Gas Unit
SYMPTOM CAUSE SOLUTION
No gas flow
Confirm LP Gas cylinder is full and valve is turned
to "open".
Check for bent or kinked regulator
Clean burner ports.
Faulty Hose Valve Regulator
Call for replacement.
Burner is off the valve
Re-engage burner onto the valve.
Spider webs or obstruction in
burner tube
Clean burner tube. Use a soft wire brush to clear
plugged ports
Burner ports blocked Clean burner ports.
Faulty Burner
Call for replacement.
Check to see if electrode is producing spark. The
spark should be visible and jumping from the
ignitor to the burner. If you cannot see any spark
you may need to slightly adjust the position by
bending the electrode a little closer or further
away from the burner. Replace ignitor or replace
the ignitor wire. Call Dansons for replacement.
Check to make sure your battery in your igniter is
good. Refer to owners manual for replacement
Check to see if burner will match light.
Ir
regular flame pattern.
Flame does not run the full
diameter of burner
Burner ports blocked
Clean burner ports. Use a soft wire brush to
clear plugged ports
Burner may be blocked
Clean burner ports.
Spider webs or obstruction in
burner tube
Clean burner tube.
Food residue or grease on
burner
Clean burner.
Burner is off the valve R
e-engage burner onto the valve.
Fuel/Air mixture incorrect
You may need to adjust the primary air shutter to
allow more air into the burner
Burner may have residue
Turn burner to high setting for 5 mins and burn
with the door open.
Burner will not light or stay
alight
Obstruction of gas flow
Bad ignitor spark
Flame is yellow or orange
TROUBLESHOOTING
44