9.    
Parts Required:
1 x Grease Bucket
(#14)
Installation:
Place the grease bucket on the spout hook on the end of the main barrel.
Ensure it is level to avoid grease spills. The unit is now completely assembled.
10.     
NOTE: Before plugging your Pit Boss into any electrical outlet, ensure the
temperature dial is in the OFF position.
 
This appliance requires 110 volt, 60hz, 275w, 5 amp service. It must be a
3-prong grounded plug. Ensure grounded end is not broken off before use.
The control uses a 5 amp, 120 volt, fast-blow fuse to protect the board from
the igniter.
 
This appliance will work on most GFCI outlets, with a recommended size
of 15 amp service. If your GFCI outlet is highly sensitive to power surges,
it will likely trip during the start-up phase of operation. During the start-
up phase, the igniter draws 200-700 watts of electricity which can be too
much power for a GFCI outlet to handle. Each time it trips, it increases in
sensitivity. If the GFCI keeps tripping, replace the outlet or change to a non-
GFCI outlet.
  
Disconnect the igniter from the main wiring harness. Use the manual start-
up procedure. A Pit Boss unit can operate using a 12 volt, 100 watt inverter
plugged into your automobile outlet. To use the automatic igniter, it is
recommended to use a minimum of a 1000 watt inverter.
IMPORTANT: Disconnect unit from power source when not in use.
10
 ,
5 
9
14