Users Manual

( For MAX BR1 Classic CB IEC 62368-1 )
Output of the external power source shall complied with ES1 and ES2 requirements, output rating 10-30
Vdc, minimum 12W ( DC Jack or POE injector ), with minimum ambient temperature 65 , altitude =
5000m , and evaluated in accordance to UL/EN/IEC 60950-1 and / or UL/EN/IEC 62368-1
Ensure to connect the power cord of power adapter to a socket-outlet with earthing.
( For MAX BR1 Mini HW3 CB IEC 62368-1 )
Output of the external power source shall complied with ES1 and PS2 requirements, input rating 10-30
Vdc, maximum 18W ( DC Power Port) or 802.3at PoE, with minimum ambient temperature 65 ,
altitude = 5000m , and evaluated in accordance to UL/EN/IEC 60950-1 and / or UL/EN/IEC 62368-1.
Ensure to connect the power cord of power adapter to a socket-outlet with earthing.
The MAX BR1 Mini is investigated to IEC TR 62102 as SELV (ES1) circuits and only connected to
PoE without routing to the outside plant, including campus environment.
https://www.peplink.com
362
Copyright @ 2021 Peplink