Product Manual

This technique is beneficial in finding conductors with
unknown locations, and with no access points. Basically
you use the equipment in a way that scans the entire
ground to find all conductors in a specific area. Please
read the instructions for inductive locating before proceed-
ing.
Position the Transmitter
Lay the 800-HL Transmitter on its side, as shown below. This
will “flood” the area with signal. Turn ON the Transmitter.
Set Up the Receiver
Set up with the receiver the same as you would during induc-
tive locating. Move 5-10 feet from the transmitter, face the
transmitter with the antenna near the ground, and turn the re-
ceiver ON. Set the sensitivity control to get a LOW growl
tone.
Locate the Conductor(s)
With the receiver facing the transmitter, walk in a circle around
the transmitter. Keep a steady distance from the transmitter
and from the ground. Listen for the HIGH pitch tone areas, DO
NOT adjust the sensitivity. After locating the HIGH pitch areas,
go back and pin-point the conductors in those areas. You may
need to re-adjust the sensitivity at this step, looking for the LOW-
HIGH-LOW sound change. Mark the places with the highest
tones for further pinpointing later.
SEARCH AND SWEEP
One Person
15