STEP 1 - INSTALLING THE HEAT SENSOR
Install the Heat Sensor to the underside of the rangehood or the underside of the over-the-range
microwave (OTR).
Note: Centre the Heat Sensor so it points as directly as possible to the centre of the range.
Keep the Heat Sensor a minimum of 1cm away from any rangehood lights. Ensure that the Sensor is attached to a at,
horizontal portion of the rangehood or OTR. Mounting surface should be clean and grease-free.
1. Ensure the Heat Sensor is at room temperature. Peel off the protective backing from
the Sensor’s mounting plate and attach the Sensor to the underside of the rangehood or
OTR microwave. Ensure that the LED side of the Sensor faces you (Image 1). Remove the
Sensor from the magnetic plate (Sensor will emit a beep). Check to ensure
that the mounting plate is rmly secured by pressing on it.
2. Remove the red battery disconnection tab from the Heat Sensor (Image 2). SAVE RED TAB.
It may be required for future use. Reattach Heat Sensor to the mounting plate, be sure the
holes in the mounting plate align with the holes in the Sensor.
Image1 Heat Sensor Image 2
Red tab
COMPATIBILITY
All electric ranges including glass top, coil and induction.
For installations that:
1. Prevent the Heat Sensor from being installed directly to the underside of the rangehood or
an over-the-range microwave, or allow for less than 18” of clearance between the range and
the rangehood:
Please contact your Pioneering Technology representative for custom installation
assistance.
For indoor use only Not suitable for use in professional kitchens. Disconnect power before
installation Ensure correct Heat Sensor location Carry out test alarm.
SMARTRANGE INSTALLATION MANUAL