Installation Guide

Indoor Unit Installation Location Selection
Follow the below best practices for selecting an optimal space for installation the indoor unit:
DO NOT install the unit on a wall that is subject to vibrations.
DO NOT install the system near sources of heat, steam, or flammable gases.
DO NOT install the indoor unit in a location that is exposed to direct sunlight.
DO ensure that the inlet and outlet vents are not obstructed. The system should be able to
output air all across the room.
DO minimize the distance between the indoor and outdoor unit and install the unit in a
place where connecting the indoor and outdoor unit will be as simple as possible.
DO install the unit on a strong wall and where it is easy to drain the condensate water.
DO install the unit in a location where it will be easy to service the machine and perform
any necessary maintenance.
DO obey the following tolerances depicted in the illustration below:
Page 22
6
Indoor Unit Installation Instructions
Indoor Unit
Installation
10-15 cm (4-6in)
or more
2.0 m (80 in) or more
10-15 cm (4-6 in)
or more
10-15 cm (4-6 in) or more