Measurement Guide



 _______________________
 _______________________


YN009GLFI22RPD / WT009GLFI22HLD





Cooling Mode Performance
Interior Unit (Air Handler) Specications
Heating Mode Performance
System Full Set Model: WYT009GLFI22RL
AHRI Reference Number: 207743768

Rated Cooling
Airow Rate (cfm)
Auto Air Circulation
9000 BTU/hr
382 (Hi) / 324 (Med) / 265 (Lo)
Sound Level (dBA)
Weight (Lbs)
39 (Hi) / 34 (Med) / 29 (Lo) / 27 (Mute)
19.8
Dimensions (WDH)
32”-1/4 x 7”-5/8 x 12”
2-Way Louver (Up-Down + Left-Right)
Ambient Range
SEER Rating
EER Rating
23.0 BTU/W·h
13.0 BTU/W·h
5°F ~ 122°F
Rated Heating 9500 BTU/hr
Ambient Range
HSPF IV (V)
COP
10.0 (8.0) BTU/W·h
3.5 W/W
-13°F ~ 86°F
Piping and Refrigerant
Liquid Line (OD)
1/4”
Suction Line (OD)
Refrigerant Precharge
Max Length/Height Di.
R410a (10 - 25 ft.)
50 Ft. / 33 Ft.
3/8”
Electrical Information
Rated Input (W)
710
730
Rated Current (A)
Breaker Needed
Power Supply
10A (double-pole)
208~230V, 1Ph, 60Hz
Cooling
Heating
3.2 3.3
* 100% Capacity @ Indoor DB 80°F/WB 66°F / Outdoor DB 95°F/WB 75°F / m.w. 16’ lineset
*High Heat (47°F) = 9500 BTU / Low Heat (17°F) = 5900 BTU / COP(5°F) = 1.75
Exterior Unit (Condenser) Specications
Airow Rate (cfm)
Metering Device
Compressor
1,235
Sound Level (dBA)
Weight (Lbs)
50.0
51.4
Dimensions (WDH)
28”-5/8 x 12” x 21-5/8”
Capillary Tube
Rotary
This combination is
Energy-Star® certied.

Summary of content (3 pages)