Troubleshooting Guide
Table Of Contents
- 01 Cover Page
- 02 Table of Contents
- 03 Table of Contents
- 04 Safety Precautions
- 05 Safety Precautions
- 06 Safety Precautions
- 07 Safety Precautions
- 08 Safety Precautions
- 09 Safety Precautions
- 10 Specs 01: Contents
- 11 Specs 02: Model References
- 12 Specs 03: Refrigerant Pipe
- 13 Specs 04: Refrigerant Cycles
- 14 Specs 05: Refrigerant Cycles
- 15 Specs 06: Refrigerant Cycles
- 16 Specs 07: Refrigerant Cycles
- 17 Specs 08: Electrical Wiring Diagrams
- 18 Specs 09: Electrical Wiring Diagrams
- 17 Specs 10: Electrical Wiring Diagrams
- 20 Specs 011: Electrical Wiring Diagrams
- 21 Specs 012: Electrical Wiring Diagrams
- 22 Specs 013: Electrical Wiring Diagrams
- 23 Specs 014: Electrical Wiring Diagrams
- 24 Specs 015: Electrical Wiring Diagrams
- 25 Specs 016: Electrical Wiring Diagrams
- 26 Specs 017: Electrical Wiring Diagrams
- 27 Specs 018: Electrical Wiring Diagrams
- 28 Specs 019: Electrical Wiring Diagrams
- 29 Specs 020: Electrical Wiring Diagrams
- 30 Specs 021: Electrical Wiring Diagrams
- 31 Specs 022: Electrical Wiring Diagrams
- 32 Specs 023: Electrical Wiring Diagrams
- 33 Specs 024: Electrical Wiring Diagrams
- 34 Features 01: Contents
- 35 Features 02: Display
- 36 Features 03: Safety
- 37 Features 04: Basic Functions
- 38 Features 05: Basic Functions
- 39 Features 06: Basic Functions
- 40 Features 07: Basic Functions
- 41 Features 08: Basic Functions
- 42 Maintenance 01: Contents
- 43 Maintenance 02: Installation Check
- 44 Maintenance 03: Installation Check
- 45 Maintenance 04: Refrigerant Recharging
- 46 Maintenance 05: Reinstallation
- 47 Maintenance 06: Air Purging with Vacuum
- 48 Maintenance 07: Evacuation
- 49 Maintenance 08: Refrigerant Charging
- 50 IDU Disassembly 01: Contents
- 51 IDU Disassembly 02: Dimensions
- 52 IDU Disassembly 03: 9-24 Front Panel
- 53 IDU Disassembly 04: 9-24 Front Panel
- 54 IDU Disassembly 05: 9-24 Front Panel
- 55 IDU Disassembly 06: 9-24 Front Panel
- 56 IDU Disassembly 07: 9-24 Front Pane
- 57 IDU Disassembly 08: 9-24 Front Panel
- 58 IDU Disassembly 09: 9-24 Electrical
- 59 IDU Disassembly 10: 9-24 Electrical
- 60 IDU Disassembly 11: 9-24 Electrical
- 61 IDU Disassembly 12: 9-24 Electrical
- 62 IDU Disassembly 13: 9-24 Evaporator
- 63 IDU Disassembly 14: 9-24 Evaporator
- 64 IDU Disassembly 15: 9-24 Fan Motor
- 65 IDU Disassembly 16: 9-24 Fan Motor
- 66 IDU Disassembly 17: 9-24 Louver Motor
- 67 IDU Disassembly 18: 9-24 Drain Hose
- 68 IDU Disassembly 19: 30-36 Front Panel
- 69 IDU Disassembly 20: 30-36 Front Panel
- 70 IDU Disassembly 21: 30-36 Front Panel
- 71 IDU Disassembly 22: 30-36 Front Panel
- 72 IDU Disassembly 23: 30-36 Front Panel
- 73 IDU Disassembly 24: 30-36 Front Panel
- 74 IDU Disassembly 25: 30-36 Electrical
- 75 IDU Disassembly 26: 30-36 Electrical
- 76 IDU Disassembly 27: 30-36 Electrical
- 77 IDU Disassembly 28: 30-36 Electrical
- 78 IDU Disassembly 25: Evaporator
- 79 IDU Disassembly 26: Evaporator
- 80 IDU Disassembly 27: Fan Motor
- 81 IDU Disassembly 28: Louver Motor
- 82 IDU Disassembly 29: Louver Motor
- 83 IDU Disassembly 30: Drain Hose
- 84 ODU Disassembly 01: Contents
- 85 ODU Disassembly 02: Reference Table
- 86 ODU Disassembly 03: Dimensions
- 87 ODU Disassembly 04: Dimensions
- 88 ODU Disassembly 05: Dimensions
- 89 ODU Disassembly 06: Dimensions
- 90 ODU Disassembly 07: Panel Plate
- 91 ODU Disassembly 08: Panel Plate
- 92 ODU Disassembly 09: Panel Plate
- 93 ODU Disassembly 10: Panel Plate
- 94 ODU Disassembly 11: Panel Plate
- 95 ODU Disassembly 12: Panel Plate
- 96 ODU Disassembly 13: Panel Plate
- 97 ODU Disassembly 14: Panel Plate
- 98 ODU Disassembly 15: Panel Plate
- 99 ODU Disassembly 16: Electrical
- 100 ODU Disassembly 17: Electrical
- 101 ODU Disassembly 18: Electrical
- 102 ODU Disassembly 19: Electrical
- 103 ODU Disassembly 20: Fan
- 104 ODU Disassembly 21: Fan
- 105 ODU Disassembly 22: Insulation
- 106 ODU Disassembly 23: Four Way Valve
- 107 ODU Disassembly 24: Compressor
- 108 ODU Disassembly 25: Compressor
- 109 T/S 01: Contents
- 110 T/S 02: Contents
- 111 T/S 03: Safety Caution
- 112 T/S 04: Error Codes
- 113 T/S 05: Error Codes
- 114 T/S 06: Error Codes
- 115 T/S 07: Complaint Record Form
- 116 T/S 08: Complaint Record Form
- 117 T/S 09: Information Inquiry Status
- 118 T/S 10: Information Inquiry Status
- 119 T/S 11: Information Inquiry Status
- 120 T/S 12: Information Inquiry Status
- 121 T/S 13: Field Maintenance
- 122 T/S 14: Remote Maintenance
- 123 T/S 15: Remote Maintenance
- 124 T/S 16: Field Maintenance
- 125 T/S 17: Field Maintenance
- 126 T/S 18: Quick Maintenance
- 127 T/S 19: E0 EH00 EH0A F4 EC51
- 128 T/S 20: E1 EL01
- 129 T/S 21: E1 EL01
- 130 T/S 22: E2 EH02
- 131 T/S 23: E3 EH03 F5 EC07
- 132 T/S 24: Fan Motors Check
- 133 T/S 25: Fan Motors Check
- 134 T/S 26: E4 EH60 E5 EH61 F1 EC53 F2 EC52 F3 EC54 F6 EC56
- 135 T/S 27: E7 EH0b
- 136 T/S 28: EC EL0C
- 137 T/S 29: F0 PC08
- 138 T/S 30: P0 PC00
- 139 T/S 31: P1 PC01
- 140 T/S 32: P2 PC02
- 141 T/S 33: P2 PC02
- 142 T/S 34: P4 PC04
- 143 T/S 35: P6 PC03
- 144 T/S 36: P6 PC03
- 145 T/S 37: Sensors; Compressor Check
- 146 T/S 38: Compressor Check
- 147 T/S 39: IPM
- 148 T/S 40: Four Way Valve Check
- 149 T/S 41: EEV Check
- 150 Apendix 01: Contents
- 151 Appendix 02: Temp Sensor Resistance Values
- 152 Appendix 03: Temp Sensor Resistance Values
- 153 Appendix 04: System Pressure
- 154 Appendix 05: System Pressure
- 155 Appendix 06: System Pressure
Safety Precautions 3
2. Information Disclosures
(For flammable materials)
2.1 Checks to the area
• Prior to beginning work on systems containing flammable
refrigerants, safety checks are necessary to ensure that the
risk of ignition is minimized.
• For repair to the refrigerating system, the following
precautions shall be complied with prior to conducting work
on the system.
2.2 Work procedure
• Work shall be undertaken under a controlled procedure so
as to minimise the risk of a flammable gas or vapour being
present while the work is being performed.
2.3 Work procedure
• All maintenance staff and others working in the local area
shall be instructed on the nature of work being carried out.
• Work in confined spaces shall be avoided.
• The area around the work space shall be sectioned off.
Ensure that the conditions within the area have been made
safe by control of flammable material.
2.4 Checking for presence of refrigerant
• The area shall be checked with an appropriate refrigerant
detector prior to and during work, to ensure the technician
is aware of potentially flammable atmospheres.
• Ensure that the leak detection equipment being used is
suitable for use with flammable refrigerants, i.e. no sparking,
adequately sealed or intrinsically safe.
2.5 Presence of fire extinguisher
• If any hot work is to be conducted on the refrigeration
equipment or any associated parts, appropriate fire
extinguishing equipment shall be available to hand.
• Have a dry powder or CO2 fire extinguisher adjacent to the
charging area.
2.6 No ignition sources
• No person carrying out work in relation to a refrigeration
system which involves exposing any pipe work that contains
or has contained flammable refrigerant shall use any sources
of ignition in such a manner that it may lead to the risk of
fire or explosion.
• All possible ignition sources, including cigarette smoking,
should be kept sufficiently far away from the site of
installation, repairing, removing and disposal, during which
flammable refrigerant can possibly be released to the
surrounding space.
• Prior to work taking place, the area around the equipment
is to be surveyed to make sure that there are no flammable
hazards or ignition risks.
• NO SMOKING signs shall be displayed.
2.7 Ventilated area
• Ensure that the area is in the open or that it is adequately
ventilated before breaking into the system or conducting any
hot work. A degree of ventilation shall continue during the
period that the work is carried out. The ventilation should
safely disperse any released refrigerant and preferably expel
it externally into the atmosphere.
2.8 Checks to the refrigeration equipment
• Where electrical components are being changed,
they shall be fit for the purpose and to the correct
specification. At all times the manufacturer’s
maintenance and service guidelines shall be followed.
If in doubt consult the manufacturer’s technical
department for assistance. The following checks
shall be applied to installations using flammable
refrigerants:
• the charge size is in accordance with the room size
within which the refrigerant containing parts are
installed;
• the ventilation machinery and outlets are operating
adequately and are not obstructed;
• if an indirect refrigerating circuit is being used, the
secondary circuit shall be checked for the presence
of refrigerant; marking to the equipment continues
to be visible and legible.
• markings and signs that are illegible shall be
corrected;
• refrigeration pipe or components are installed in
a position where they are unlikely to be exposed
to any substance which may corrode refrigerant
containing components, unless the components
are constructed of materials which are inherently
resistant to being corroded or are suitably protected
against being so corroded.
2.9 Checks to electrical devices
• Repair and maintenance to electrical components shall
include initial safety checks and component inspection
procedures. If a fault exists that could compromise
safety, then no electrical supply shall be connected to
the circuit until it is satisfactorily dealt with. If the fault
cannot be corrected immediately but it is necessary to
continue operation, an adequate temporary solution
shall be used. This shall be reported to the owner of
the equipment so all parties are advised. Initial safety
checks shall include: