Troubleshooting Guide

Table Of Contents
parameter of EEPROM. Its value ranges from -6°C to 6°C.
When T1-Ts>-ΔT3, the compressor ceases operation.
When T1-Ts<-ΔT3-1.5°C (2.7 °F), the compressor
continues operation.
When the AC is operating in mute mode, the
compressor operates at a low frequency.
When the current exceeds the preset value, the current
protection function activates and the compressor
ceases operation.
3.5.2 Indoor Fan Control:
When the compressor is on, the indoor fan speed can
be set to high, medium, low, or auto. And the anti-
cold wind function has the priority.
Anti-cold air function
The indoor fan is controlled by the indoor
temperature T1 and indoor unit coil temperature
T2.
T2
Setting fan speed
H
M+
M
L
Super slow
Fan off
TEL0+23-
TE1
TEL0+21- TE1
TEL0+19- TE1
TEL0+17- TE1
TEL0+15- TE1
TEL0+13- TE1
TEL0+18- TE1
TEL0+16- TE1
TEL0+14- TE1
TEL0+12- TE1
TEL0+10- TE1
TEL0
T1 19°C(66.2 °F) ΔTE1=0
15 °C(59°F) T1 18 °C(64.4°F)
ΔTE1=19°C-T1
(34.2°F-T1)
T1<15 °C(59°F) ΔTE1=4 °C(7.2 °F)
When the indoor temperature T1 reaches the setting
temperature, the compressor continues operation,
the indoor fan motor runs at the minimum speed or
setting speed.(The anti-cold air function is valid).
The indoor fan is controlled as below:
Setting fan
speed
Actual fan speed
H (=H)
H+(H+=H+G)
M(M=M)
M+(M+=M+Z)
L(L=L)
L+(L+=L+D)
H- (H-=H-G)
M-(M-=M-Z)
L-(L-=L-D)
T1-Td °C(°F)
L
H
M
-
Auto fan action in heating mode:
T1-Td
3.5.3 Outdoor Fan Control:
Case 1:
The outdoor unit will be run at different fan speed
according to T4 and compressor frequency .
For different outdoor units, the fan speeds are
different.
Case 2:
The outdoor unit will be run at different fan speed
according to T4.
For different outdoor units, the fan speeds are
different.
3.5.4 Defrosting mode
Case 1:
The unit enters defrosting mode according to the
temperature value of T3 and T4 as well as the
compressor running time.
In defrosting mode, the compressor continues to run,
the indoor and outdoor motor will cease operation,
the defrost light of the indoor unit will turn on, and
the
symbol is displayed.
If any one of the following conditions is satised,
defrosting ends and the machine switches to normal
heating mode:
T3 rises above TCDE1.
T3 maintained above TCDE2 for 80 seconds.
Unit runs for 15 minutes consecutively in defrosting
mode.
Case 2:
The unit enters defrosting mode according to the
temperature value of T3 as well as the compressor
running time.
In defrosting mode, the compressor continues to run,
the indoor and outdoor motor will cease operation,
the defrost light of the indoor unit will turn on, and
the
symbol is displayed.
Product Features 6