Troubleshooting Guide

Table Of Contents
7.10 P1/PC 01(Over voltage or too low voltage protection diagnosis and solution)
Description: Abnormal increases or decreases in voltage are detected by the specified voltage detection circuit.
Recommended parts to prepare:
Power supply wires
IPM module board
PCB
Reactor
Troubleshooting and repair:
Check the power supply.
Getting proper input
voltage ?
Turn off the unit until
supply voltage is fixed.
NO
Check the connections and wires.
YES
Are they in working order ?
Ensure proper connections
or replace the wires.
NO
Power on and measure the
voltage between P and N.
YES
Replace the IPM board.
NO
Check the reactor.
YES
Is it in working order ?
Replace outdoor PCB.
YES
Replace the reactor.
NO
Skip this step for models which
electric control box cover cannot
be removed. See the disassembly
guide for details.
Troubleshooting 31
Note: For certain models, outdoor PCB cannot be removed separately. In this case, the outdoor electric
control box should be replaced as a whole.
While the unit is in standby,
is the voltage between P and N
around DC 310V, 340V or 380V?
When starting up the unit, is it
within 220V~400V?