Troubleshooting Guide

Table Of Contents
2. General Troubleshooting
2.1 Error Display (Indoor Unit)
When the indoor unit encounters a recognized error, the operation lamp will ash in a corresponding series, the
timer lamp may turn on or begin ashing, and an error code will be displayed. These error codes are described
in the following tables:
Operation
Lamp
Timer
Lamp
Display Error Information Solution
1 time
OFF
E0
Indoor unit EEPROM parameter error TS19
2 times
OFF
E1
Indoor / outdoor unit communication error
TS20
3 times
OFF
E2
Zero-crossing signal detection error(for some models)
TS22
4 times
OFF
E3
The indoor fan speed is operating outside of the normal range TS23
5 times
OFF
E4
Indoor room temperature sensor T1 is in open circuit or has short
circuited
TS26
6 times
OFF
E5
Evaporator coil temperature sensor T2 is in open circuit or has
short circuited
TS26
9 times
OFF
E7/EH 0B
Indoor PCB/Display board communication error(for some models)
TS27
7 times
OFF
EC
Refrigerant leak detected TS28
1 times
ON
F0
Current overload protection TS29
2 times
ON
F1
Outdoor room temperature sensor T4 is in open circuit or has
circuited
TS26
3 times
ON
F2
Condenser coil temperature sensor T3 is in open circuit or has
short circuited
TS26
4 times
ON
F3
Compressor discharge temperature sensor TP is in open circuit
or has short circuited
TS26
7 times
ON
F6
Evaporator coil outlet temperature sensor T2B is in open circuit or
has short circuited(for free-match indoor units)
TS26
5 times
ON
F4
Outdoor unit EEPROM parameter error TS19
6 times
ON
F5
The outdoor fan speed is operating outside of the normal range
(for some models)
TS23
1 times
FLASH
P0
IPM malfunction or IGBT over-strong current protection TS30
2 times
FLASH
P1
Over voltage or over low voltage protection TS31
3 times
FLASH
P2
High temperature protection of IPM module or High pressure
protection
TS32
5 times
FLASH
P4
Inverter compressor drive error TS34
7 times
FLASH
P6
High pressure protection or low pressure protection
(for some models)
TS35
6 times
FLASH
P5/--
Indoor units mode conict(match with multi outdoor unit) --
Troubleshooting 4
For other errors:
The display board may show a garbled code or a code undened by the service manual, such as an "88"
with the Wi-Fi symbol lighting up.
Ensure that this code is not a temperature
reading.
Troubleshooting:
Test the unit using the
remote control. If the unit does not
respond to the
remote and the wiring is correct, the
indoor PCB requires replacement. If the unit
responds, the display board
requires
replacement.