Troubleshooting Guide

Table Of Contents
7.5 E4/EH 60/E5/EH 61/F1/EC 53/F2/EC 52/F3/EC 54/F6/EC56 (Open circuit or short circuit
of temperature sensor diagnosis and solution)
Description: If the sampling voltage is lower than 0.06V or higher than 4.94V, the LED displays the failure code.
Recommended parts to prepare:
Connection wires
Sensors
PCB
Troubleshooting and repair:
Check the connection between
temperature sensor and PCB.
Replace indoor PCB((E4/EH 60/E5/EH 61)
or outdoor PCB(F1/EC 53/F2/EC 52/
F3/EC 54/F6/EC 56)
Is it within acceptable
parameters
*See Appendix
*?
Is it properly wired?
Ensure proper connections.
NO
Measure the resistance value
of the sensor.
YES
Replace the sensor.
NO
YES
Note: For certain models, outdoor PCB cannot be removed separately. In this case, the outdoor electric control box
should be replaced as a whole. This picture and the value are only for reference, actual appearance and
value may vary. For certain models, outdoor unit uses combination sensor (T3, T4 and TP are the same of sensor).
Troubleshooting 26