5.3 Checking the Calibration Results
Check that the sensor has been calibrated correctly.
5.3.1 Check that the crank is detecting no load.
In the Force Preview screen of the SGX-CA500, the figures shown should be within the following range.
Tangential Force : 0 +/- 3N
Radial Force: 0 +/- 3N
If numbers outside this range are shown, it is possible that the crank moved during
the calibration. Please retry with the crank in a stable position.