SGY-PM910H2/HL/HR Installation Manual(for dealers) 1
Table of Contents Table of Contents ...............................................................................................................................................2 1 Preparations ...................................................................................................................................................4 1.1 Confirm the products ..............................................................................................................................4 1.
.2.1 Preparations ..................................................................................................................................13 3.2.2 Detecting the Magnet Position .....................................................................................................13 3.3 4 5 Magnet Calibration (Using the SGX-CA500).................................................................................14 3.3.1 Preparations ............................................................
1 Preparations 1.1 Confirm the products The operations necessary to install the Pedaling Monitor System on the customer’s bicycle depend on which System it is; SGY-PM910HL/HR or SGY-PM910H2, and on which cycle computer is being used; SGX-CA500, SGX-CA900, or some other manufacturer’s product. 1.2 Outline of procedure 1.2.1 For the SGY-PM910HL/HR with an ANT+ cycle computer Single Power Meter Mode:(SGY-PM910Hl/HR Factory Default Mode) 1. [3.
1.2.3 For the SGY-PM910HL/HR/(HL+HR)/H2 with a SGX- CA500 Pedaling MonitorMode: 1. [3.1Temporarily affix the Magnet]: Attach the left and right magnet(s) to the frame temporarily. 2. [2.1 Mode Switching]: Switch to Pedaling Monitor Mode. Using a SGX-CA500 with Firmware of Version 20150501.02.43 or higher, input the device number of either or both sensors and switch the mode to Pedaling Monitor Mode. Once this is successful, the Sensor LED will light in Green for ten seconds. 3. [3.3.
1.3 Product mode When using SGX-CA500, the firmware version is required to be 20150501.02.43 or higher. Pedaling monitor mode: When paired with Cyclocomputer SGX-CA500, the pedaling efficiency and cadence and other such properties can be measured. You can make maximum use of the functions of this product. •Dual power meter mode: Left and right sensors are required. The actual power values of the left and right sensors can be totaled and displayed and the cadence can be measured.
2.1.4 Enter the device number and tap [ ]. The device numbers are printed on the right junction box and on the side of the left sensor. 2.1.5 Rotate the bicycle’s crank set more than three rotations to start the left and right transmitters. •Pair with the Cyclocomputer within 5 minutes after the transmitters are activated. 2.1.6 Tap [Pedaling Monitor]. The search for the sensor starts. A [Please wait.] message appears.。 •It may take more than 1 minute to pair with the sensor.
2.2 Switch to dual power meter mode • Both the left and right sensors are required in this mode. Cyclocomputer SGX-CA500 is required when the sensor changes to the pedaling monitor mode. It cannot be switched by using cyclocomputers from other manufacturers. •The firmware version of SGX-CA500 needs to be 20150501.02.43 or higher. If it is of a different version, update the firmware. Refer to the User's Guide (For WEB) of SGX-CA500 regarding how to update. http://pioneer-cyclesports.
By pushing the push switch in the right transmitter for more than 3 seconds, the LEDs on the right transmitter blink green. When communication with the left transmitter is enabled, the LEDs on the left and right transmitters rapidly blink orange. Confirm that the LEDs on the left and right transmitters blink when the mode is switched. (If they do not blink, the communication may have been done with another pedaling monitor sensor by mistake.
2.2.2 [Method 2] Switch the mode on SGX-CA500 Go to the mode switching screen. 2.2.2.1 If the left and right sensors are checked, tap [Dual Power]. The mode switching completion screen opens. In this state, the cyclocomputer is still not paired with the sensor. If the mode cannot be switched, refer to 2.1.7Add in the sensor list of SGX-CA500. When the mode is switched, the LEDs of the sensors light orange for 10 seconds.
2.3 Switch to single power meter mode ・If the actual sensor mode is pedaling monitor mode, switch it on SGX-CA500. ・The firmware version of SGX-CA500 needs to be 20150501.02.43 or higher. If it is of a different version, update the firmware. Refer to the User's Guide (For WEB) of SGX-CA500 regarding how to update. http://pioneer-cyclesports.com/us-en/support/products/ The mode can be switched in two ways. Select according to the actual sensor mode.
3 Magnet Detection and Calibration 3.1 Temporarily affix the Magnet 3.1.1 Use masking tape to temporarily attach the Magnet Patch The adhesive on the back of the Magnet Patch is very strong, so do not remove the backing paper until the Magnet position is confirmed. In most cases, the Magnet Patches should be Attach the magnet so that when used rather than the Arm Type.
3.1.3 Temporarily affix the Magnet. For the left and right sides, try to affix the magnet so that it is within 1.5mm and 10.7mm of the sensor. If this is not possible on the Chainstay, try the Seat Tube (right photo) or the Down Tube. If this distance range cannot be achieved, try using the Magnet Patch Spacer. 3.1.4 Turn the crank slowly. Check that the magnet does not come in contact with the senso. 3.
3.3 Magnet Calibration (Using the SGX-CA500) When using both left and right sensors with the SGX-CA500 cycle computer, Magnet Calibration is necessary. ・Magnet Calibration allows the sensors to detect the precise position of the magnet. This is essential for correct display of the force vectors so please ensure that it is done correctly. ・Magnet Calibration requires the SGX-CA500 cycle computer. It cannot be done with other cycle computers. Also, the sensors must be in Pedaling Mode.
3.3.3 Fixing the Magnets Being careful not to move the Magnets from their measured position, fix the Magnets in place. Remove the masking tape on one side of the Magnet only. Remove the backing tape on the back of the Magnet, and affix it permanently to the position in which it had been temporarily affixed. 3.3.4 Magnet Calibration After 3.3.3Fixing the Magnets, then Magnet Calibration is performed. Press [Calibration Start].
4 Pairing with the Cyclocomputer This section describes how to pair the installed pedaling monitor sensors on your bicycle to the SGX-CA500 Cyclocomputer. If you are using this product with a Cyclocomputer from another manufacturer, the method of pairing is different. Refer to the User’s Manual of the Cyclocomputer you are using. In the chapter“ 2.1.7Add in the sensor list of SGX-CA500 ", already, if you are paired, the following process is not required. 4.1 Check the sensor modes.
4.4 Press [Search]. If the [Error Rate] shows an [OK} result, then connection has been successful. If the search continues for more than a minute, go back to 4.1Check the sensor modes. 1 to restart the sensor and try the search again.. Pairing of the right transmitter is completed. Pair the left transmitter in the same way.
5 Zero Calibration Zero Calibration can be performed using the Cycle Computer SGX-CA500 1 Place the bicycle in a vertical, level position (Both wheels at the same height)using a roller or stand. 2 Rotate the crank at least three times to start up both sensors. 3 Place the crank arm in a vertical position (with the pedals attached) 5.1 Select Zero Calibration. On the SGX-CA500, press the [Menu] button, then select [Options] -> [Pedaling Settings] ->[ZeroCal]. 5.
5.3 Checking the Calibration Results Check that the sensor has been calibrated correctly. 5.3.1 Check that the crank is detecting no load. In the Force Preview screen of the SGX-CA500, the figures shown should be within the following range. Tangential Force : 0 +/- 3N Radial Force: 0 +/- 3N If numbers outside this range are shown, it is possible that the crank moved during the calibration. Please retry with the crank in a stable position.
6 Copy pedal Copy pedal is enabled only in pedaling monitor mode. If only the sensor on one side is operating, you can copy the data on the other side also to display it for both sides on the Cyclocomputer and record it in the log. You can select copy pedal of the current bike and set the balance. 6.1 6.2 Press the menu button on the CycloMeter screen. Tap [Option] then [Pedaling settings] and then [Pedaling Copy].,and select the copy method. 6.3 6.4 To change the balance, tap [L:R Balance].
7 Operation Check(Using the SGX-CA500 only) Using the pedaling monitor mode only:• After Completing 3.3Magnet Calibration and 5Zero Calibration ride the bicycle to confirm that the Pedaling Vectors are shown correctly on the CycloComputer Display. If the Vector directions are not correct, it is possible that Magnet Calibration was not done correctly, so try again. If the Vectors are not shown, check if the sensors are in Power Meter Mode.
8 Troubleshooting Pedaling Monitor Sensor SGYPM910H2/HL/H R Question A long push on the button in the right transmitter does not change the Mode. Answer The operation of the Mode Change function is different in the SGYPM910H2. The same is true if the firmware of the SGY-PM910H has been updated.
Question Pedaling Monitor Cannot connect to a cycle computer from Sensor another manufacturer in SGYPM910H2/HL/H Dual PowerMeter Mode. R Cannot switch from Dual Power Meter Mode to Single PowerMeter Mode. Answer In Dual Power meter Mode, the sensor device number uses the device number of the right side sensor for both sensors The SGY-PM910H cannot operate in Single Power Meter Mode. An update of the firmware is necessary in order to use Single Power Meter Mode.
Cyclecomputer Question There is no menu for switching modes. It is not possible to switch modes using the SGXCA500. The display shows [Timeout]. It is not possible to switch modes using the SGXCA500. The display shows [Low Battery]. In Magnet Calibration Mode on the SGX-CA500, the count does not rise even though the crank is rotated. Answer Update the SGX-CA500 cyclecomputer to the latest firmware version.
Cyclecomputer Question In Magnet Calibration Mode on the SGX-CA500, the results of the calibration cannot be stored. Answer Once the count increasing with each rotation has been confirmed, with the magnets attached temporarily, Fix the magnets in place and press the [Measure] button. The display will show the count as 0/5. Rotate the crank until the display count is shown as 5/5, then the [Save] button will become available. Magnet Calibration must be completed within thirty minutes.
9 Error Code (Using the SGX-CA500) An error code is displayed if an error occurs while doing calibrations. Code Description of error 2 Insufficient battery power 3 There is a possibility of disconnection. Correspondence Battery exchange Please contact your dealer or service representative. 1.it is possible that the crank moved during the calibration. Please retry with the crank in a stable position 2. Communication status is likely to be poor.