Full Product Manual

2. SPECIFICATIONS
6
NOTE:
1. Test conditions:
1.1 Rated capacity test conditions:
Cooling: Indoor: DB 80.0℉ (26.7C) /WB 67.0℉ (19.4C)
Outdoor: DB 95.0℉ (35.0C) /WB 75.0℉ (23.9C)
Heating: Indoor: DB 70.0℉ (21.1
C) /WB 60.0℉ (15.6C)
Outdoor: DB 47℉ (8.3C) /WB 43℉ (6.1
C)
1.2 SEER & HSPF test standard: AHRI 210/240.
2. The Sound Pressure Level is based on the following conditions:
Outdoor unit
Measure the noise value of 3 pointswhich are1 meter in front of the three sides of the unit surface
(front/left/right) and 1/2(unit height +1) meter high from floor level, and calculate the weighted average of the noise.
3. The above data was measured in an anechoic chamber. Please take into consideration the reflected sound of your specific
application environment.
4. All specifications are subjected to change by the manufacturer without prior notice.
Outdoor Model AUWR-24U3SF1 AUWR-36U3SA1
AUWR-60U3SP1
Rated Current(RLA) A 9.45 9.45
15.39
Refrigerant Oil
ml VG74 /670 VG74 /670
VG74 /1000
oz. VG74 /22.7 VG74 /22.7
VG74 /33.9
Refrigerant
Type/Quantity
Type R-410A R-410A
R-410A
Refrigerant Charge
kg 2 2.8
4.05
oz. 70.5 98.7
142.9
Factory Precharge Ft. 25 25
25
Additional Charge for Each Ft. oz. 0.376 0.376
0.6
Refrigerant
Piping
Liquid Line OD mm/in
Φ9.52(3/8') Φ9.52(3/8')
Φ9.52(3/8')
Vapor Line OD mm/in Φ15.88(5/8') Φ19.05(3/4')
Φ22.22(7/8')
Max. Pipe Length
m 50 75
Ft. 164 246
Max. Difference in Level
m 30 30
30
Ft. 98 98
98
DIMENSIONS & WEIGHT
Outdoor Unit
Dimension (W×H×D)
mm 860×670×310
950×840×340
950×1386×340
in 33-7/8×26-3/8×12-1/4 37-3/8×33-1/8×13-3/8
37-3/8×54-5/8×13-3/8
Packing (W×H×D)
mm 990×730×450
1110×920×460
1110×1530×460
in 39×28-3/4×17-3/4 43-3/4×36-1/4×18-1/8
43-3/4×60-1/4×18-1/8
Net Weight
kg 51
114
lbs 112.4
251.3
Shipping Weight
kg 55
126
lbs 121.3
277.5
Qty’per 20’ /40’ /40'HQ (Outdoor Unit) Set 90/186/186
52/106/106
26/53/53
Compressor
75
246
76
167.5
71
156.5