Full Product Manual

2.�SPECIFICATIONS
Type Twin ROTARY Twin ROTARY Twin ROTARY Twin ROTARY
Capacity Btu/h 26085 26085 41865 41865
Input W 2080 2080 3385 3385
Rated current(RLA) A 9.45 9.45 15.39 15.39
Refrigerant oil
ml VG74 /670 VG74 /670 VG74 /1000 VG74 /1000
oz VG74 /22.7 VG74 /22.7 VG74 /33.9 VG74 /33.9
Refrigerant
type/Quantity
Type R-410A R-410A R-410A R-410A
Refrigerant charge oz(kg) 70.5(2.0) 98.7(2.8) 142.9(4.05) 142.9(4.05)
Factory precharge
Ft(m) 25(7.6) 25(7.6) 25(7.6) 25(7.6)
Additional charge for
each ft
oz/ft 0.38 0.38 0.6 0.6
Outdoor unit
Dimension(W×H×D)
mm 860×670×310 950×840×340 950×1386×340 950×1386×340
inch
33-7/8×26-3/8×
12-1/4
37-3/8×33×13-3/8
37-3/8×54-5/8×
13-3/8
37-3/8×54-5/8×
13-3/8
Packing(W×H×D)
mm 990×730×450 1110×920×460 1110×1530×460 1110×1530×460
inch 39×28-3/4×17-3/4
43-3/4×36-1/4×
18-1/8
43-3/4×60-1/4×
18-1/
8
43-3/
4×60-1/4×
18-1/8
Net weight
kg
51.0 67.0 103.0 114.0
lbs
112.4 147.7 227.1 251.3
Shipping Weight
kg
55.0 72.0 115.0 126.0
lbs
121.3 158.7 253.5 277.5
Design
pressure
H/L
MPa 3.8/1.6 3.8/1.6 3.8/1.6 3.8/1.6
PSIG 550/240 550/240 550/240 550/240
Refrigerant
piping
Liquid side/ Gas side mm(inch)
Φ9.52/Φ15.88
(3/8'/5/8')
Φ9.52/Φ19.05
(3/8'/3/4')
Φ9.52/Φ22.22
(3/8'/7/8')
Φ9.52/Φ22.22
(3/8'/7/8')
Max. pipe length
m 50 75 75 75
ft 164 246 246 246
Max. difference in
level
m 30 30 30 30
ft 98 98 98 98
Operating
temperature
range
Cooling
5-122 5-122 5-122 5-122
-15-50 -15-50 -15-50 -15-50
Heating
-13-75 -13-75 -13-75 -13-75
-25 - 24 -25 - 24 -25 - 24 -25 - 24
Qty’per 20’ /40’ /40'HQ
(Outdoor unit)
Set 90/186/186 52/106/106 26/53/53 26/53/53
Outdoor model 24K 36K 48K 60K
NOTE:
1. Test conditions:
1.1 Rated capacity test conditions:
Cooling: Indoor: DB 80.0℉ (26.7C) /WB 67.0℉ (19.4C)
Outdoor: DB 95.0℉ (35.0C) /WB 75.0℉ (23.9
C)
Heating: Indoor: DB 70.0℉ (21.1C) /WB 60.0℉ (15.6C)
Outdoor: DB 47℉ (8.3C) /WB 43℉ (6.1C)
1.2 SEER & HSPF test standard: AHRI 210/240.
2. The Sound Pressure Level is based on the following conditions:
Outdoor unit
Measure the noise value of 3 points
which are1 meter in front of the three sides
of the unit surface
(front/left/right) and 1/2(unit height
+
1) meter high from floor level
,
and calc
ulate the weighted average of the noise.
3. The abov
e data was measured in an anechoic chamber. Please take into co
nsideration the reflected sound of your specific
application environment.
4.
All specifications are subject to change by the manufacturer without prior notice.
Compressor