Manual

TROUBLESHOOTING
Symptom
No recordfng_
Previous sound remains
when recording a'new
No treble sound,
Possible cause
* Cassette tape's accidental erasure prevention tab
broken off
Boosted treble
= When the COPY switch _s turned to "ON," the
program signals from the LiNE INPUT (REC)
jacks cannot record
REC LEVEL controf set too low (no indication of
the revel meter during recording)
Disconnected or improper stereo amplifier con*
nection,
Dirty head
Dirty heads
A tape, which was not recorded with the Dofby
NR system, is being played back at ON position
of DOLBY NR switch,
With deck I1, the positions of the TAPE SELEC_
sw_tches do not match the tape being
TOR
used
Dirty heads,
A taps, which was recorded with the Dolby NR
system, is being played back at OFF position of
DOLBY NR switch
With deck II, the pes{tlons of the TAPE SELEC_
TOR [_ switches do not match the tape
being
used,
Remedy
Cover tab hote with adhesive tape (see page 7)
Cover with adhesive tape
Turn the COPY switch to "OFF "
OFF
Adjust the REC LEVEL control as i_dicated on
page 8 and record
Check a_l connections (see page 3'_
Clean heads (see page 16)
Pinch roi_er
Combination head,capstan
', Clean heeds (see page I6)
Set DOLBY NR switch to proper position
Setthe TAPE SELECTOR_switches to match
the tape being used {See page 6 )
Ctean heads {see page 16)
Set DOLBY NR switch to proper poshion
Set the TAPE SELECTOR C_] switches to match
the tape being used (See page 6 }
18
<RRB.276>