Manual
TROUBLESHOOTING
Symptom
No recordfng_
Previous sound remains
when recording a'new
No treble sound,
Possible cause
* Cassette tape's accidental erasure prevention tab
broken off
Boosted treble
= When the COPY switch _s turned to "ON," the
program signals from the LiNE INPUT (REC)
jacks cannot record
• REC LEVEL controf set too low (no indication of
the revel meter during recording)
• Disconnected or improper stereo amplifier con*
nection,
• Dirty head
Dirty heads
• A tape, which was not recorded with the Dofby
NR system, is being played back at ON position
of DOLBY NR switch,
• With deck I1, the positions of the TAPE SELEC_
sw_tches do not match the tape being
TOR
used
• Dirty heads,
A taps, which was recorded with the Dolby NR
system, is being played back at OFF position of
DOLBY NR switch
With deck II, the pes{tlons of the TAPE SELEC_
TOR [_ switches do not match the tape
being
used,
Remedy
Cover tab hote with adhesive tape (see page 7)
Cover with adhesive tape
Turn the COPY switch to "OFF "
OFF
Adjust the REC LEVEL control as i_dicated on
page 8 and record
Check a_l connections (see page 3'_
Clean heads (see page 16)
Pinch roi_er
Combination head,capstan
', Clean heeds (see page I6)
• Set DOLBY NR switch to proper position
Setthe TAPE SELECTOR_switches to match
the tape being used {See page 6 )
• Ctean heads {see page 16)
• Set DOLBY NR switch to proper poshion
Set the TAPE SELECTOR C_] switches to match
the tape being used (See page 6 }
18
<RRB.276>