Data Sheet
CONFIDENTIAL
BDR-209EBK October 29, 2013
Revision 1.00 JB-U0395/JB-K0520
11 / 28
6. Environmental Conditions
6.1.
Temperature and Humidity
Drive condition
Drive conditionDrive condition
Drive condition
Test items
Test itemsTest items
Test items
Min.
Min.Min.
Min.
Typ.
Typ.Typ.
Typ.
Max.
Max.Max.
Max.
Units
UnitsUnits
Units
Remarks
RemarksRemarks
Remarks
Operation
Temperature +5 - +45 °C
within 10°C/hour deviation
within 10%/hour deviation
No condensation
Humidity 5 - 85 %RH
Wet Bulb Temp.
- - 29 °C
Non-Operation
Temperature -20 - +60 °C
within 10°C/hour deviation
within 10%/hour deviation
No condensation
Storage period: 96H
Before connecting DC
power on a drive after low
temperature storage, leave
the drive 4 hours in the
room temperature after the
storage condition.
Humidity 5 - 85 %RH
Wet Bulb Temp.
- - 29 °C
Transportation
(packaging
condition)
Temperature -40 - +60 °C
within 20°C/hour deviation
within 20%/hour deviation
No condensation
Storage period: 96H
Before connecting DC
power on a drive after low
temperature storage, leave
the drive 4 hours in the
room temperature after the
storage condition.
Humidity 5 - 85 %RH
Wet Bulb Temp.
- - 29 °C