To Set or Adjust Temperature Limit Stop
Caution: Ceramic Cartridge is preset at the factory at maximum tempera-
ture. Adjust as necessary. Please see the instructions below:
10. Turn off water and relieve the pressure. Remove handle (P) by
removing button (N) and loosening Allen screw (O) and lift off
the handle (P).
11. Unscrew retainer sleeve (Q) and retaining nut (R) counter
clockwise.
12. Use two î‚¿ngers raise the red adjustment ring (S). Turn adjust
ment ring (S) counterclockwise to decrease the temperature
setting and clockwise to increase the temperature. Replace.
13 &14. Reassemble and test until desired safe temperature is reached.
(Note: Ensure proper alignment of cartridge with notch in valve
body.)