Installation Guide
6
REV-01 17, 13
Trim Installation
Turn off the main water supply1.
Remove test cap (F) with the help of 1-11/32” socket, ensure all the 2.
debris are ushed out of the system. relieve the water pressure.
Thread sleeve (G) to the valve body. Insert the cartridge (H) to the 3.
valve body. Ensure the ‘UP’ symbol on the cartridge is on the top.
Ensure the two notches underneath of the cartridge seats properly
in the valve body. Hold the cartridge (H) and thread the locknut(I) to
sleeve(G). Thread retainer cap (J) to locknut (I).
For back to back installation:- Rotate the cartridge 180 degree. Ensure 4.
‘B-B UP’ symbol on the cartridge is on the top. Follow the instruction
on 3 to install sleeve (G), locknut (I) and retainer cap (J).
Turn on the water supply. Check for any leak. Turn the cartridge (H) 5.
counterclockwise to the full open position. Allow water to run for some
time until the hot water comes out. Check the temperature with ther-
mometer for the hot water.
If necessary to reduce the hot water temperature then, turn off water 6.
supply. Remove the cartridge by removing retainer cap(J) and locknut
(I). Turn red temperature adjusting ring (K) clockwise to decrease the
temperature. Follow instruction 3 or 4 to reassemble the cartridge(H).
Ensure the hot water temperature is set below 120 ° F.