Installation Guide
3
REV-11 19, 12
Valve Installation
Determine Hole Location :- This valve is designed for 8” to 20” center 1.
widespread installation. So decide the Location of the mounting hole
withinthatrange.DeterminetheD1dimensionfromthespecication
sheet for the desired trim set and add minimum 1/2” clearance from the
ledge.
For All Installation : - Refer to the drawing the required valve height from 2.
nisheddeckis1-3/4”andmaximumdeckthicknessis2”andshank
heightis1-3/8”.Note:-extensionkitisavailableforthickerDeck.Drill
three 1-1/2” diameter holes.