Full Product Manual

33
pinnacolopizzaovens.com
TESTED IN ACCORDANCE WITH ANSI Z21.58-2018 • CSA 1.6-2018 STANDARD FOR OUTDOOR COOKING GAS APPLIANCE.
THIS OVEN IS FOR OUTDOOR USE ONLY.
OVEN INSTALLATION CODES
Check your local building codes for the proper method of installaon. In the absence of local codes, this unit should be installed in
accordance with the Naonal Fuel Gas Code, ANSI Z223.1/NFPA 54, Storage and Handling of Liqueed Petroleum Gases, ANSI /NFPA
B149.2 or CSA B149.1 Natural Gas and Propane Installaon Code, and the Naonal Electrical Code, ANSI/NFPA 70.
CORRECT LPG TANK USE
LPG oven models are designed for use with a standard 9.07 kg (20 lb). Liquid Propane Gas tank, not included with oven. Never connect
your gas oven to an LPG tank that exceeds this capacity.
NOTE: The normal ow of gas through the regulator and hose assembly can create a humming noise.
A low volume of noise is perfectly normal and will not interfere with operaon of the oven. If humming
noise is loud and excessive you may need to purge air from the gas line or reset the regulator excess gas
ow device. This purging procedure should be done every me a new LPG tank is connected to your oven.
Visually check the burner ames prior to each use.
The ames should look like this picture. If they do not,
refer to the burner maintenance part of this manual.
SAFETY INSTRUCTIONS
Do not try lighng this appliance without reading the “LIGHTING INSTRUCTIONS” secon of this manual.
WARNING
CAUTION: Spiders and small insects occasionally spin webs
or make nests in the oven burner tubes during transit and
warehousing. These webs can lead to gas ow obstrucon,
which could result in a re in and around burner tubes.
This type of re is known as “FLASH-BACK” and can cause
serious damage to your oven and create an unsafe operang
condion for the user.
Although an obstructed burner tube is not the only cause of
“FLASH-BACK”, it is the most common cause.
To reduce the chance of “FLASH-BACK”, you must clean the
burner tubes before assembling your oven, and at least once
a month in late summer or early fall when spiders are most
acve. Also perform this burner tube cleaning procedure if
your oven has not been used for an extended period of me.
A clogged tube can lead to a re beneath the oven.
CAUTION: BEWARE OF FLASHBACK
Pinnacola_Gas_PizzaOven_Manual_BLK.indd 33Pinnacola_Gas_PizzaOven_Manual_BLK.indd 33 2021-07-02 3:24 PM2021-07-02 3:24 PM