TESTED IN ACCORDANCE WITH ANSI Z21.58-2018 • CSA 1.6-2018 STANDARD FOR OUTDOOR COOKING GAS APPLIANCE.
THIS OVEN IS FOR OUTDOOR USE ONLY.
OVEN INSTALLATION CODES
Check your local building codes for the proper method of installaon. In the absence of local codes, this unit should be installed in
accordance with the Naonal Fuel Gas Code, ANSI Z223.1/NFPA 54, Storage and Handling of Liqueed Petroleum Gases, ANSI /NFPA
B149.2 or CSA B149.1 Natural Gas and Propane Installaon Code, and the Naonal Electrical Code, ANSI/NFPA 70.
CORRECT LPG TANK USE
LPG oven models are designed for use with a standard 9.07 kg (20 lb). Liquid Propane Gas tank, not included with oven. Never connect
your gas oven to an LPG tank that exceeds this capacity.
NOTE: The normal ow of gas through the regulator and hose assembly can create a humming noise.
A low volume of noise is perfectly normal and will not interfere with operaon of the oven. If humming
noise is loud and excessive you may need to purge air from the gas line or reset the regulator excess gas
ow device. This purging procedure should be done every me a new LPG tank is connected to your oven.
Visually check the burner ames prior to each use.
The ames should look like this picture. If they do not,
refer to the burner maintenance part of this manual.
SAFETY INSTRUCTIONS
Do not try lighng this appliance without reading the “LIGHTING INSTRUCTIONS” secon of this manual.
WARNING
CAUTION: Spiders and small insects occasionally spin webs
or make nests in the oven burner tubes during transit and
warehousing. These webs can lead to gas ow obstrucon,
which could result in a re in and around burner tubes.
This type of re is known as “FLASH-BACK” and can cause
serious damage to your oven and create an unsafe operang
condion for the user.
Although an obstructed burner tube is not the only cause of
“FLASH-BACK”, it is the most common cause.
To reduce the chance of “FLASH-BACK”, you must clean the
burner tubes before assembling your oven, and at least once
a month in late summer or early fall when spiders are most
acve. Also perform this burner tube cleaning procedure if
your oven has not been used for an extended period of me.
A clogged tube can lead to a re beneath the oven.
CAUTION: BEWARE OF FLASHBACK
Pinnacola_Gas_PizzaOven_Manual_BLK.indd 33Pinnacola_Gas_PizzaOven_Manual_BLK.indd 33 2021-07-02 3:24 PM2021-07-02 3:24 PM