Installation Guide

10
Press to turn pump speed down. Minimum speed is 1.
Press once to turn pulsating pump mode ON. Pump speed varies automatically every 10 seconds. Press a second time to turn
pulsating pump mode OFF.
Press once to turn lights ON, Press a second time to turn lights OFF.
Press once to turn air blower and lights ON. When button is pressed, the blower speed increases gradually for 5 seconds before
it returning to default setting. The “+”, “-” and “mode buttons are disabled during start up. Press a second time to turn blower OFF.
The blower times out automatically after 20 minutes.
Press to turn blower speed up. Maximum speed is 10.
Press to turn blower speed down. Minimum speed is 1.
Press to turn blower mode on. Press a second time to turn blower mode o.
Each press changes the light color.
Adjusting Flow from Large Jets: The large jets can be adjusted from relaxing to rejuvenating and
everything in between. Rotate the jets counter clockwise to increase the ow of water - clockwise to
reduce it.
Controlling the Aromatherapy: When the dispenser in your signature bath is lled with aromatherapy crystals, the scent is
automatically dispersed when the blower is turned on. To ll the dispenser, turn the cap counterclockwise to remove it, deposit
aromatherapy crystal pouch into the dispenser, replace the cap and turn it clockwise to tighten it. To stop the scent from being
released, remove the pouch or turn the blower o.
Controlling the Waterfall: Your signature bath is equipped with a continuous ow waterfall. When the pump is turned on, water will
automatically begin owing and will continue owing until the pump is turned o. To increase the ow of water, rotate the waterfall
valve counter clockwise. Turning the dial counter clockwise will decrease the ow. The waterfall valve cannot to stop the ow of water,
since the waterfall is designed to ow continuously.
IMPORTANT FOR WHIRLPOOL BATHS EQUIPPED WITH THE OPTIONAL IN-LINE HEATER:
The in-line heater turns on automatically when the pump is turned on and all jets are fully open.
The in-line heater is designed to maintain the water temperature and prevent heat loss that occurs during normal operation. It is not
designed to heat cold water to comfortable bathing temperatures.
The in-line heater will shut down automatically if the high limit sensor detects the water temperature has exceeded safe limits and will
remain disabled until it has cooled suciently for the switch to reset automatically. The easiest way to reset the heater is to turn the
circuit breaker o until it has cooled. Contact an electrician if the high limit sensor trips repeatedly.
CLEANING YOUR SIGNATURE BATH
Automatic Purge Cycle: To remove water in the air jets, a purge cycle will begin automatically 15 minutes after the system stops. The
lower will run on high speed and stop automatically after 2 minutes. If no water is detected it will stop automatically. During the 2
minute drying cycle, the buttons on the topside are disabled and the LED will display the time remaining in seconds, counting down
from 120 seconds.
After each use, clear hair and lint from the suction cover and rinse your bath well.
Clean frequently with a soft cloth and mild liquid detergent mixed with warm water. Rinse well after cleaning.
Once each month, ll your bath with hot water above the jets and add a sanitizer safe for acrylic surfaces following the instructions on
the label. Turn the pump on, run for 10 minutes and drain. Fill bath with cold water 2” above the jets, turn on, run for 15 minutes and
drain. *Never use dish soap, hand soap, laundry detergent or any other cleaner that creates suds.
10
Increase
Decrease
Controling Flow from Large Jets