Certifications 2
Good general ventilation (typically 10 air changes per hour) should be used.
Ventilation rates should be matched to conditions.
If applicable, use process enclosures, local exhaust ventilation, or other engineering controls to
maintain airborne levels below recommended exposure limits.
If exposure limits have not been established, maintain airborne levels to an acceptable level.
Ventilation should be sufficient to effectively remove and prevent buildup of any dusts or fumes
that may be generated during handling or thermal processing. If engineering measures are not
sufficient to maintain concentrations of dust particulates below the OEL (occupational exposure
limit), suitable respiratory protection must be worn.
Ensure adequate ventilation, especially in confined areas.
Appropriate engineering controls
Appropriate engineering controlsAppropriate engineering controls
Appropriate engineering controls
Individual protection measures, such as personal protective equipment
Individual protection measures, such as personal protective equipmentIndividual protection measures, such as personal protective equipment
Individual protection measures, such as personal protective equipment
Personal protection equipment should be chosen according to the CEN standards and in
discussion with the supplier of the personal protective equipment. Eye wash fountain is
recommended. Keep working clothes separately. Launder contaminated clothing before reuse.
General information
General informationGeneral information
General information
Wear safety glasses with side shields (or goggles). Avoid contact with eyes. Use tight fitting
goggles if dust is generated. (EN166)
Eye wash fountain is recommended.
Eye/face protection
Eye/face protectionEye/face protection
Eye/face protection
Skin protection
Skin protectionSkin protection
Skin protection
Suitable gloves can be recommended by the glove supplier. (EN374) Use protective gloves made
of: PVC or other plastic material gloves.
- Hand protection
- Hand protection- Hand protection
- Hand protection
Normal work clothing (long sleeved shirts and long pants) is recommended.
Personal protection equipment should be chosen according to the CEN standards and in
discussion with the supplier of the personal protective equipment.
- Other
- Other- Other
- Other
If engineering controls do not maintain airborne concentrations below recommended exposure
limits (where applicable) or to an acceptable level (in countries where exposure limits have not
been established), an approved respirator must be worn. When workers are facing concentrations
above the exposure limit they must use appropriate certified respirators. Respirator type FFP2 or
FFP3 (EN 149:2001)
Respiratory protection
Respiratory protectionRespiratory protection
Respiratory protection
None known.Thermal hazards
Thermal hazardsThermal hazards
Thermal hazards
Do not get this material in contact with eyes. Do not breathe dust. When using, do not eat, drink or
smoke. Avoid contact with eyes.
Always observe good personal hygiene measures, such as washing after handling the material
and before eating, drinking, and/or smoking. Routinely wash work clothing and protective
equipment to remove contaminants.
Hygiene measures
Hygiene measuresHygiene measures
Hygiene measures
No special measures required Avoid release to the environment.Environmental exposure
Environmental exposureEnvironmental exposure
Environmental exposure
controls
controlscontrols
controls
SECTION 9: Physical and chemical properties
SECTION 9: Physical and chemical propertiesSECTION 9: Physical and chemical properties
SECTION 9: Physical and chemical properties
9.1. Information on basic physical and chemical properties
9.1. Information on basic physical and chemical properties9.1. Information on basic physical and chemical properties
9.1. Information on basic physical and chemical properties
Dry flowable granules.Appearance
AppearanceAppearance
Appearance
Solid.Physical state
Physical statePhysical state
Physical state
Granules
Beads
Form
FormForm
Form
White.Colour
ColourColour
Colour
Odourless.Odour
OdourOdour
Odour
Odour threshold
Odour thresholdOdour threshold
Odour threshold Not available.
pH
pHpH
pH Not applicable
Melting point/freezing point
Melting point/freezing pointMelting point/freezing point
Melting point/freezing point Not applicable
Initial boiling point and boiling
Initial boiling point and boilingInitial boiling point and boiling
Initial boiling point and boiling
range
rangerange
range
Not applicable
Flash point
Flash pointFlash point
Flash point Not applicable.
Evaporation rate
Evaporation rateEvaporation rate
Evaporation rate Not applicable
Not available.Flammability (solid, gas)
Flammability (solid, gas)Flammability (solid, gas)
Flammability (solid, gas)
Upper/lower flammability or explosive limits
Upper/lower flammability or explosive limitsUpper/lower flammability or explosive limits
Upper/lower flammability or explosive limits
Flammability limit - lower
Flammability limit - lowerFlammability limit - lower
Flammability limit - lower
(%)
(%)
(%)
(%)
Not applicable
S
D
S
UK
4 / 8
Material name: PINGI CAR-DEHUMIDIFIER LV-A150 - LV-A300, LV-A350, LV2-A350, 350SDA, LV-B300, LV-B450, LV3-
B450, ASB-1000 1363 Version #: 03 Revision date: 18-March-2018 Issue date: 17-March-2015








