VII — ROUTINE MAINTENANCE
VII — ROUTINE MAINTENANCE
The following KEY MAINTENANCE AND PERFORMANCE CHECKS should be made monthly or
more frequently in some environments where dust is a problem:
TRANSMITTER
Remove and clean the air filters with a light detergent and dry completely before re-installing. Dirty
filters will cause PA amps to shutdown resulting in a loss of RF Power. Spare filter P/N 990199 is
available from Pineapple Technology Inc.
Check and record the Voltage and Current meter readings on the ACDIS2 (AC AND DC DISTRIBU-
TION UNIT LOCATED NEAR THE POWER SUPPLIES). NOTE: current readings will vary with
picture content.
Using the ADP500 & PAS10 record the bias level settings on each PA Pallet by selecting the appropri-
ate PA with the selector switch. To make this measurement of BIAS ONLY it is necessary to activate
the PA INHIBIT switch momentarily for each reading.
Using the ADP500 check and record the RF Output power level to insure that it is still reading 100%
+/- 10% from the previous settings.
Using the ADP500 check and record the VSWR (Reflected power) to insure that it is still reading only a
few percent indicating normal load operations.
Using the ADP500 check and record Aural power readings. This is normally set at 10% of P-Sync.
Expect this to vary only a few percent from reading to reading.
Carefully inspect RF Output coax and coaxial fittings for excessive heating or discoloration
FACILITIES
Clean all air inlet filters and exhaust outlets to insure that the transmitter is getting clean unobstructed
air flow.
Perform recommended service on air condition systems
Rodent traps or baits should be renewed to keep the facilities clear of these pests which can damage to
the transmitter