IX — PROBLEM SOLVING/TROUBLE SHOOTING
FAN FAULT indications could mean that the PA blower has failed or there has been a loss of AC power
to the fan. There is also a fuse located just inside of the front panel in case there is a locked rotor failure
condition. To locate and check this fuse it is necessary to remove the MFA1KW from the rack so that the
top cover can be removed. The fuse is behind the front panel near the fan.
ADP500: There are a number of fault indicator lights on this unit that can be used for trouble shooting
possible problems with the transmitter.
With normal operating conditions, all the LEDs located on the front panel should be green. Red lights
could indicate a fault in normal operations of the transmitter. Fault indicators are listed below:
a. ANT VSWR HIGH light is RED. This indicated that the antenna reected power exceeds the set point
in the equipment which is normally set to 10%. When this LED is on, the transmitter shutdown line
is pulled down to ZERO and the transmitter RF PWR OFF LED will also light RED indicating that
the transmitter has been shutdown at the driver level. This condition will automatically reset when the
problem is corrected. CHECK THE ANTENNA FOR POSSIBLE FAULTS.
b. RF PWR OFF light is RED. This will occur anytime the “SHUTDOWN LINE” is pulled to ZERO.
This control line is pulled to ZERO with any of the following faults:
1. ANT VSWR HIGH
2. PA INHIBIT SWITCH IN THE INHIBIT MODE
NOTICE: ONLY THE PA INHIBIT SWITCH OR THE ANT VSWR HIGH WILL SHUTDOWN THE
TRANSMITTER DRIVE CAUSING THE RF OUTPUT TO FALL TO NEAR ZERO.
c. PA1 THRU PA5 LEDs RED would indicate that the PA Pallet current level has fallen below the set
point and could indicate a transistor failure. The normal current with the “inhibit” switch activated
is 500 ma.
RR6000 POWER SUPPLY MODULES
The Power Supply module has two warning lights located on the front panel. Normally these lights are
GREEN indicating that the AC Line voltage and the Over Voltage circuits are within their normal range.
Should either go out of range, the lights will turn RED and the power supply module will shutdown. This
will reduce the available power to the RF Stages and could result in lower RF Output Power from the
transmitter. If this happens, turn off the transmitter for about 1 minute and then turn it back on. If this
warning continues, the module should be removed from the rack and returned for service and a spare
module should be installed to maintain normal operations.
NOTICE: The UTX5KW-A transmitter has nine (9) 2 KW power modules. Under normal conditions, this
is enough head room to allow the removal of one power supply module with little or no reduction in output
power. In the event it becomes necessary to remove a module and the RF Output power drops, the RF
Drive level from the modulator can be reduced to a point where the DC Volt meter on the AUX5 reads
31 volts. This is the maximum output level obtainable with one power supply module removed. On
this transmitter that could be a reduction of less than 500 watts in operational output power. This will
keep the station on the air until the new power supply module arrives. DON’T FORGET TO TURN
THE DRIVE LEVEL UP AFTER INSTALLING THE NEW SUPPLY TO RETURN TO 100%